Herunterladen Diese Seite drucken

Buhnen HB 700 K Betriebsanleitung Seite 20

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Starting
3.1.2
Connecting up (operation with working bracket/workstation)
To connect up the device proceed as follows:
1. Place the device in the working bracket.
2. Attach the working bracket's compressed-air connection (1) (see illustration on p. 3) to
the compressed-air supply.
Observe the requirements made of the compressed-air supply (Section 1.2, „Technical
data").
3. Set the operating pressure to 4 bar with the pressure regulator (3).
4. Connect the mains plug to a socket outlet with earthing contact.
The device is now ready for use.
3.2
Switching on
To switch the device on press and hold the Start/Stop button (6) for at least 1 s.
The digital display lights up and indicates the current temperature. The device heats up
immediately to the preset temperature (target temperature). The decimal point on the left
flashes until the target temperature has been reached.
The target temperature can be displayed by pressing the Set button (7).
3.3
Settings on the temperature regulator
3.3.1
Setting the working temperature
1. To set the working temperature press the Set button. The current working temperature
is displayed.
2. Hold the Set button down. Select the required working temperature using the Up/Down
buttons.
Briefly pressing the Up or Down button changes the working temperature in steps of
1°C per button-press. Pressing the button for longer changes the working temperature
continuously.
The new setting is saved automatically when the buttons are released.
3.3.2
Reading out and setting the control parameters
Pressing the Up and Down buttons simultaneously for at least 4 s brings up a parameter
list. Some parameters can be set, others only read out. The table below summarises the
parameters:
Para-
Function
meter
P1
Setpoint lowering
If the device is not used for some time, the
temperature regulator automatically switches to
operation at lowered temperature. A temperature
is adjusted to which is below the set working
temperature by the value set here.
P2
Waiting time before setpoint lowering
If the device is not used for longer than the time
set here, temperature lowering starts.
P11
Hours-run counter
The hundreds, tens and units digits are displayed.
P12
Hours-run counter
The thousands digits are displayed.
P13
Number of actuations
The hundreds, tens and units digits are displayed.
P14
Number of actuations
The thousands digits are displayed.
Settable
1...999 min
-
-
-
-
20
GB
Setting
Standard
range
value
1...100 °C
40 °C
30 min
Customer