Fig. 6
Fig. 7
A - See vent manufacturer instructions
Exhaust gas discharge channel
The stove requires a CE listed pellet vent. So the venting system shall be approved for pellet
stoves by a certified testing laboratory.
PL Vent must be used for venting all Free-standing stoves.
Do not use to vent pellet appliance these venting materials and products:
- Dryer vent
- Gas appliance (Type B) vent
- PVC (plastic) pipe
- Single wall stovepipe.
The pellet stove is not the same as other stoves. It has a forced draught of flue gas by a fan,
which keeps the firebox in a vacuum and the entire exhaust gas discharge channel slightly
pressurize. For this reason, the flue must be completely airtight and correctly installed to
ensure both trouble-free operation and user safety.
• The exhaust gas discharge channel must be made by specialized personnel or firms, as
outlined below.
• The flue must be installed in such a way as to guarantee that periodic cleaning can be
carried out without dismantling any parts whatsoever.
• Pipes should always be sealed with silicone (not cement-based sealants) or specially
adapted gaskets/seals, which retain their strength and elasticity at high temperatures
(>450°F/230°C) and should be fixed with at least three sheet metal screws.
Using the relative pipe clips, fix the flue to the wall so that it does not weigh on the smoke
fan.