Instructions for using Saunatonttu heater's control panel
Switch the power on by the O/I switch at the lower left of the heater.
When the heater is switched on, the simmering level 1 turns on and its indicator LED lights up. (1st on the bottom row)
Press the on - off switch once; all the indicator lights go off and the control panel is in a wait state.
Press the same switch again; the zero light lights up and the control panel is operable.
Choose the preferred simmering level by using the lower arrow key. The light indicates the selected level.
In absence of an indicator light all simmering levels are off.
Simmering levels: 1. 100W, 2. 200W and 3. 300W
NOTE:
Simmering level cannot be changed when the timing or lid control is on.
When on lid control, the simmering level is always 2 and cannot be changed.
Lid control
To select lid control press the left arrow key to light up the green indicator light K.
When the sauna heater is cold, the following happens when the lid is closed:
- The power switches on and the top indicator lights 4, 5 and 6 light up.
- Simmering level 2 is automatically on.
- Once the heater is heated up, the power turns off, the indicator lights 4, 5 and 6 go off and the simmering
level 2 maintains the heat.
After you've opened the lid for taking a sauna bath, the power will turn on in ~3-5 minutes, if the temperature sensor allows.
When you close the lid, the power will turn off in ~3-10 minutes depending on the temperature, and the simmering level 2
maintains the heat.
NOTE:
When you choose the lid control, the control panel will automatically leave the lid control mode and return to the zero
mode in six hours, if the lid is not closed before that.
(Each time you open the lid, the six hour period restarts and makes sure the heater safely returns to the zero mode, if
you accidentally leave the lid open after taking a sauna bath.)
You can leave the lid control by pressing the right arrow key once so that the zero light lights up and the green lid control indicator
light K turns off.
Timing
The heater can be timed by pressing the right arrow key for timing of 15, 30 or 60 minutes, indicated by a light. The upper indicator
lights 4, 5 and 6 light up and the power will turn on for the chosen time, after which the control panel will automatically return to
the zero mode. The simmering level, if selected, maintains the heat. If you want to turn the timing off earlier, press the left arrow
key until the zero light lights up.
The indicator light at the top of the heater will turn off, when the thermostat resets (the heater in max temperature).
10