Herunterladen Diese Seite drucken

TESY GCV 1004724D C21 TS2RC Gebrauchsanleitung Und Pflege Seite 8

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 22
I.
IMPORTANT RULES
EN
1.
This technical description and instructions manual was prepared in order to acquaint you with the product and the conditions of proper installation and
use. These instructions were also intended for use by qualified technicians, who shall perform the initial installation, or disassembly and repairs in the event of a
breakdown.
2.
Following the current instructions will primarily be of interest to the consumer, but along with this, it is also one of the warranty conditions, pointed out in the
warranty card, so that the consumer can benefit from the free warranty services. The producer is not responsible for damages in the appliance that have appeared
as a result of operation and/or installation not corresponding to the instructions here.
3.
The electric water heater complies with the requirements of EN 60335-1, EN 60335-2-21.
4.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
5.
Children shall not play with the appliance.
6.
Cleaning and user maintenance shall not be made by children without supervision.
Attention! Improper installation and connection of the appliance may make it hazardous for the health and life of consumers. It may
cause grievous and permanent consequences, including but not limited to physical injuries and/or death. Improper installation and
connection of the appliance may also lead to damage to the consumers' property /damage and/ or destruction/, or to that of third persons,
as a result of, but not limited to flooding, explosion and/or fire.
Installation, connection to the main water and power supply, and putting into operation must be carried out by certified electricians and technical
personnel certified in installation of this category of appliances, who have obtained their license in the state where the installation and commissioning
of the appliance are carried out, and in compliance with its local legislation.
All alterations and modifications to the water heater's construction and electrical circuitry are forbidden. If such alterations or modifications are established
during inspection, the appliance's warranty shall be null and void. Alterations and modifications shall mean each instances of removal of elements incorporated
by the manufacturer, building in of additional components into the water heater, replacement of elements by similar elements unapproved by the manufacturer.
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
1.
The water heater must only be mounted in premises with normal fire resistance.
2.
In the event the device is mounted in a bathroom, the selected location must exclude the possibility of water spray contact from the showerhead or portable
showerhead attachment.
3.
The water heater is designed to operate only in closed and heated premises where the temperature is not lower than 4°C and it is not designed to operate in a
continuous protracted regime.
4.
The appliance is affixed to a wall via the mounting brackets attached to the unit's body (if the brackets are not attached to the unit's body, they must be affixed in
place via the provided bolts).
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
1.
The appliance is intended to supply hot water to household sites equipped with a piping system working at pressure below 6 bar (0,6 Mpa).
2.
.The safety return-valve must be mounted on the cold water supply pipe, in observance of the direction arrow stamped on its body, indicating the incoming
water's direction. Additional stopcocks must not be mounted between the safety return-valve and the water heater.
Exception: If the local regulations (norms) require the usage of another protection valve or mechanism (in accordance with EN 1487 or EN 1489), then it must be
bought additionally. For mechanisms operating in accordance with EN 1487 the announced operational pressure must be no more than 0.7 MPa. For other protection
valves, the pressure at which they are calibrated must be 0.1 MPa lower than the one marked on the appliance's sign. In these cases the safety valve which the appliance
is supplied with should not be used.
3.
The safety valve and the pipe between the valve and the water heater must be protected from freezing. During hose draining - its free end must be always open
to the atmosphere (not to be immersed). Make sure that the hose is also protected from freezing.
4.
In order to secure the water heater's safe operation, the safety return-valve must undergo regular cleaning and inspections for normal functioning /the valve
must not be obstructed/, and for the regions with highly calcareous water it must be cleaned from the accumulated lime scale. This service is not provided under
warranty maintenance.
5.
In order to prevent injury to user and third persons in the event of faults in the system for providing hot water, the appliance must be mounted in premises
outfitted with floor hydro insulation and plumbing drainage. Don't place objects, which are not waterproof under the appliance under any circumstances. In
the event of mounting the appliance in premises not outfitted with floor hydro insulation, a protective tub with a plumbing drainage must be placed under the
appliance.
6.
During operation – regime of heating the water – water drops through the drainage opening of the protection valve are usual. The protection valve should be left
open to the atmosphere. Measures should be taken to lead and collect the leakages in order to prevent damages.
7.
If the probability exists for the premise's temperature to fall below 0°С, the water heater must be drained.
In the event you must empty the water heater, first you must cut off its power supply. The inflow of water from the water mains must first be terminated and the hot
water tap of the mixing-faucet must be opened. The water tap 7 (fig 4) must be opened to drain the water from water tank. If there is no such tap build in the pipe
line, than the water can be drain directly from inlet pipe of water tank after when you disconnect it from water main.
8.
These instructions shall also apply to water heaters equipped with a heat exchanger - Section VII. These are appliances with inbuilt heat exchanger and are
intended to be connected to the heating system with maximum temperature of the heat carrier of 80°C.
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
1.
Do not switch on the water heater unless you established it was filled with water..
2.
Upon connecting the water heater to the electric mains care must be taken to connect the safety lead.
3.
Models without power cord, the circuit has to be supplied with a safety fuse (16A) and with inbuilt device to ensure disconnection of all pole pieces in the
conditions of over-voltage from category III.
4.
If the power supply cord (of models that have one) is damaged, it must be replaced by a service representative or a person with similar qualification, to avoid any
risk.
5.
For water heaters intended for horizontal mounting the power supply conductor insulation from fixed wiring must be protected from direct contact with
the flange (in zone under the plastic panel). For example, insulating sleeving having temperature rating higher than 90 °C can be used.
6.
During the heating the appliance could produce a hissing noise (the boiling water). This is common and does not indicate any damage. The noise gets higher with
the time and the reason for this is the accumulation of limestone. To remove the noise the appliance must be cleaned from limestone. This type of cleaning is not
covered by the warranty.
The TESY team would like to congratulate you on your new purchase. We hope that your new appliance shall bring more comfort to your home.
6
Instructions for use and maintenance
Mounting
Water heater connection
Connection to the electrical network
Dear Clients,