Problem
The display shows Error 60
The display shows Error 61
The display shows Error G1
The display shows Error 00001
The display shows Error 00002
The display shows Error 00003
The display shows Error 00004
The display shows Error 00001
16 Disposal
NOTICE! Protect the environment
All operating fluids and components may only be disposed of by qualified personnel in accordance with
national regulations.
Disposing of used fluids
• Used oil is hazardous waste.
• Do not mix used oil with other fluids.
• Prior to disposal keep used oil in suitable containers.
Disposing of packaging material
• Dispose of the cardboard packaging material with other waste paper.
• Dispose of plastic packaging material with other recyclable waste.
Disposal of the old A/C service unit
• If you wish to dispose of the A/C service unit, first completely drain it of all liquids and dispose of them ac
cording to national regulations.
• Have the old A/C service unit disposed of by qualified personnel in accordance with national regulations or
contact the customer service.
Possible cause
During the hybrid service (flushing the
service hoses with hybrid oil), a vacu
um could not be achieved.
Pressure increase during the hybrid
service (flushing the service hoses
with hybrid oil).
A connection to the analysis module
could not be made.
The readings are unstable.
The readings are excessively high.
Calibration with the ambient air failed.
The device is operating outside the
recommended temperature range.
The refrigerant sample has a very high
content of air or the amount of refriger
ant was too low for testing.
Suggested remedy
Are the service hoses connected
to the hybrid flush container?
Is the hybrid flush container fitted
the right way round?
Check the connections for leaks.
Are the service hoses connected
to the hybrid flush container?
Is the hybrid flush container fitted
the right way round?
Are the service couplings open?
Check the connections.
Are the LEDs on the module acti
vated?
Keep possible electrical sources
of interference, such as mobile
phones or welding equipment,
away from the device.
Keep possible electrical sources
of interference, such as mobile
phones or welding equipment,
away from the device.
Ensure the device is adequately
ventilated.
Leave any leaking refrigerant to
drain off.
Only use the device in tempera
turecontrolled rooms (10 °C – 45
°C).
Ensure sufficient ventilation.
Ensure that there is enough refrig
erant pressure.
Ensure that all the hoses are con
nected, not kinked and free of oil.
EN