12 Initial startup
This chapter describes the procedures you have to carry out before you can operate the A/C service unit.
12.1 Setting up and switching on
Note In order to achieve correct measurements, the A/C service unit must be placed on a level flat sur
face during operation. Ignore any error codes which occur during commissioning (Troubleshooting on
page 37) and skip by pressing
1. Wheel the A/C service unit to the workplace and lock the front wheels.
2. Mount the service hoses.
3. Set the length of the service hoses (Setting the length of the service hoses on page 12).
4. Connect the A/C service unit to the power supply.
5. To switch the A/C service unit on, set the main switch to
The switchon delay runs for 35 s and the housing is ventilated. The software version number then appears in
the display for several seconds:
10
ENTER
.
I
.