12 Equipment Data

1
Type and order code
2
Design
2.1
Degree of protection according to EN 60 529
2.2
Installation location
3
Performance data
3.1
Operating temperature limits:
Heating water flow
Brine (heat source)
Antifreeze
Minimum brine concentration (-13 °C freezing temperature)
3.2
Temperature spread of heating water (flow/return flow)
3.3
Heat output / COP
3.4
Sound power level
3.5
Sound pressure level at a distance of 1 m
3.6
Heating water flow with an internal pressure differential of
3.7
Brine throughput with an internal pressure differential (heat source) of
3.8
Refrigerant / total filling weight
3.9
Lubricant / total filling weight
4
Dimensions, connections and weight
4.1
Device dimensions without connections
4.2
Device connections to heating system
4.3
Device connections to heat source
4.4
Weight of the transportable unit(s) incl. packing
5
Electrical connection
5.1
Nominal voltage; fuse protection
5.2
Nominal power consumption
5.3
Starting current with soft starter
Nominal current B0 W35 / cos 
5.4
5.5
max. power consumption of compressor protection (per compressor)
6
Complies with the European safety regulations
7
Additional model features
7.1
Water in device protected against freezing
7.2
Performance levels
7.3
Controller internal/external
1. Operation with 2 compressors.
2. This data indicates the size and capacity of the system according to EN 255 or EN 14511. For an analysis of the economic and energy efficiency of the system, both the bivalence
point and the regulation should also be taken into consideration. The specified values, e.g. B10 / W55, have the following meaning: Heat source temperature 10 °C and heating
water flow temperature 55 °C.
3. Operation with 1 compressor.
4. Minimum heating water flow rate
5. Recommended heating water flow rate and brine throughput
6. Note that additional space is required for pipe connections, operation and maintenance.
7. See CE declaration of conformity
8. The heat circulating pump and the heat pump manager must always be ready for operation.
www.dimplex.de
at B0 / W35
at B-5 / W55
at B0 / W45
at B0 / W50
at B0 / W35
6
1
B0 W35
2
8
452234.66.10 · FD 9407
°C
°C
1
K
2
1
kW / ---
3
kW / ---
2
1
kW / ---
3
kW / ---
2
1
kW / ---
3
kW / ---
2
1
31.2 / 4.6
kW / ---
3
14.4 / 4.2
kW / ---
dB(A)
dB(A)
m³/h / Pa
2.6
m³/h / Pa
7.0
type / kg
type / litres
H x W x L mm
Inch
Inch
kg
V / A
kW
A
12.23 / 0.8
A / ---
W
SI 30TE
SI 30TE
IP 21
Indoors
up to 58 ± 2
-5 to +25
Monoethylene glycol
25%
10.0
5.2
24.7 / 2.4
9.0 / 1.7
28.7 / 3.3
12.0 / 2.7
28.1 / 2.9
11.3 / 2.4
30.3 / 4.4
14.1 / 4.1
62
46
4
5
/ 1100
5.0
/ 2500
5
5
/6000
7.0
/6000
R404A / 7.7
Polyolester (POE) / 3.54
1660 x 1000 x 775
G 1 1/2'' internal/external
G 2'' internal/external
365
400 / 20
6.78
6.91
25
12.72 / 0.8
70
7
Yes
2
Internal
EN-11