ry charger.
4. In the section entitled „Charger indicator" you
will fi nd a table with an explanation of the LED
indicator on the charger.
The battery pack can become a little warm during
the charging. This is normal.
If the battery pack fails to charge, check:
•
whether there is voltage at the socket outlet
•
whether there is good contact at the charging
contacts
If the battery pack still fails to charge, send
•
the charging unit
•
and the battery pack
to our customer service center.
To ensure that items are properly packaged
and delivered when you send them to us,
please contact our customer service or the
point of sale at which the equipment was
purchased.
When shipping or disposing of batteries and
cordless tools, always ensure that they are
packed individually in plastic bags to prevent
short circuits and fi res.
To ensure that the battery pack provides long ser-
vice, you should take care to recharge it promptly.
You must recharge the battery pack when you
notice that the performance of the device drops.
Never allow the battery pack to become fully di-
scharged. This will cause it to develop a defect.
Battery capacity indicator (Fig. 8)
Press the button for the battery capacity indicator
(Item A). The battery capacity indicator (Item B)
shows the charge status of the battery using 3
LEDs.
All 3 LEDs are lit:
The battery is fully charged.
2 or 1 LED(s) are lit:
The battery has an adequate remaining charge.
1 LED fl ashes:
The battery is empty, recharge the battery.
All LEDs blink:
The battery temperature is too low. Remove the
battery from the equipment, keep it at room tem-
perature for one day. If the fault reoccurs, this me-
Anl_Rasarro_36_34_SPK13.indb 22
Anl_Rasarro_36_34_SPK13.indb 22
GB
ans that the rechargeable battery has undergone
exhaustive discharge and is defective. Remove
the battery from the equipment. Never use or
charge a defective battery.
Installing the battery (Fig. 9)
Open the battery cover. Then insert the batteries
in the mounts as shown in Fig. 9.
Important!
The equipment's operating time depends on
the battery with the lower charge level or lower
capacity (Ah). Therefore, only use rechargeable
batteries which are charged to the same level and
have the same capacity (Ah). Never combine full
and half-full batteries or batteries with diff erent
capacities (Ah). Always charge the two batteries
simultaneously before starting to use them.
Close the battery cover by fl ipping the cover
down.
6. Operation
Caution!
The lawn mover is equipped with a safety circuit
to prevent unauthorized use. Directly before star-
ting up the lawn mover insert the safety plug (Fig.
10/Item 3) and remove the safety plug again whe-
never you interrupt or terminate your work.
Important!
To prevent the equipment switching on acciden-
tally, the lawn mower is equipped with a safety
switch (Fig. 11/Item 16) which must be pressed
before the switching bar (Fig. 11/Item 1) can be
activated. The lawn mower switches itself off
when the switching bar is released. The start time
can amount to several seconds. Repeat this pro-
cess several times so that you are sure that the
machine functions properly. Before you perform
any repair or maintenance work on the equip-
ment, ensure that the blade is not rotating and
that the safety plug is disconnected.
Caution! Never open the chute fl ap when the
grass bag has been detached (to be emptied)
and the motor is still running. A rotating bla-
de can cause serious injuries!
Always carefully fasten the chute fl ap and grass
basket. Switch off the engine before emptying the
grass basket.
- 22 -
15.06.2022 10:29:04
15.06.2022 10:29:04