48.21130000-0000 00009 REKTA 30 The installation and operation of this luminaire are subject to the national safety regulations. During installation and re-lamping, the power supply must be disconnected. High voltage on LEDs is possible till 1 minute after power disconnection !!! Voor de installatie en werking van dit armatuur dient men rekening te houden met de nationale veiligheidsvoorschriften.
Seite 2
Schließen Sie die Erdungskabel der Abdeckprofile und/oder Raster wieder an. • Geeignete Maßnahmen gegen ESD (elektrostatische Entladung) müssen genommen werden • Geschikte ESD (elektrostatische ontlading) beschermingsmaatregelen moeten genomen worden. MULTILINE Licht nv Europaweg 1 – B – 3560 Questions ? Lummen Vragen ?
Seite 4
STEP 1.1 : Mounting holes are provided on the back of the base profile. Remove the cover (a) from these mounting holes with the supplied green spring (b). Method via the side (c) or via the end of the shield or at the headboard (d1-d2). The shielding is a blind plate, LED diffuser satin or microprismatic, or a BAP grid.
Seite 5
Copy the dimensions of the suspension points on the ceiling. Countersunk holes or slotted holes (a) are provided. Fasten STEP 1.3 : the base profile with chipboard screws (b) or threaded bolts (c). STAP 1.3 : Haal de maten van de ophangpunten over op het plafond. Er zijn verzonken gaten of sleufgaten (a) voorzien. Schroef het basisprofiel vast met spaanplaatschroeven (b) of draadbouten (c).
Seite 6
STEP 1.5 : With several profiles, a connection can be made (a) to the terminals (b) of the next basic profile (c). STAP 1.5 : Bij meerdere profielen kan er een verbinding gemaakt (a) worden naar de aansluitklemmen (b) van het volgende basisprofiel (c).
Seite 7
warning ! When replacing the LEDboards, make sure that no wires are pinched between the light profile and the base profile. The sheath can be damaged and there is a risk of short circuit or wire breakage. waarschuwing ! Zorg, dat er bij het terugplaatsen van de LEDboards, geen draden geklemd komen te zitten tussen het lichtprofiel en het basisprofiel.
Seite 8
STEP 2.1 : With suspended mounting, a power cable is already provided on the profile. The cable is connected to the ceiling via a canopy junction box (a). Loosen the set screws (b) of the canopy with the supplied 2mm Allen key (c). Screw the mounting plate (d) to the ceiling with chipboard screws.
Seite 9
The profile is suspended with steel wires. TYPE1 suspension is pictured here. Other TYPES can be viewed on our website. STEP 2.2 : Mark the drill holes on the ceiling where a suspension is provided. Unscrew the mounting screw (a) from the cone with a conical tool (b).
Seite 10
STEP 2.3 : Connect the power cable of the fixture to this luster terminal (a). De-double the ground wire (d) and attach one end to the ground tab (b). Then fit the cable with the supplied strain relief (c) and tighten it firmly. Bring the canopy over the mounting plate and tighten with the set screws.
Seite 11
warning ! When replacing the LEDboards, make sure that no wires are pinched between the light profile and the base profile. The sheath can be damaged and there is a risk of short circuit or wire breakage. waarschuwing ! Zorg, dat er bij het terugplaatsen van de LEDboards, geen draden geklemd komen te zitten tussen het lichtprofiel en het basisprofiel.
Seite 12
STEP 3.1 : With recessed mounting you have a base profile (a) and a magnetic profile (b). On delivery there are green strips (c) around to separate the two profiles from each other. Pull out gently to release the magnet (d) from the counter plate (e). If there are several luminaires, the open space between them is filled with a cover plate with magnets.
Seite 13
STEP 3.2 : The ground wire is screwed into the base profile (a) with an eyelet (l). Pull the slider (k) off the tab (j), which is screwed onto the magnetic profile. It comes standard with a fall protection of thin steel wire (h) with a carabiner (f). This is permanently mounted on the base profile (i).
Seite 14
STEP 3.3 : Disconnect the wiring from the magnetic profile from the terminal on the driver plate of the base profile. Press the tab and pull the wire at the same time. Pay attention to the color of the wire for reconnection. The mounting holes for the mounting bracket and the cable entry hole can then be seen in the base profile.
Seite 15
STEP 3.5 : For flush mounting you need at least 2 composite brackets (a+c). Mark the distances, corresponding to the mounting holes in the profile, on the side of the recess in the ceiling. The recess has a minimum width (e) of 43 mm and a maximum of 45 mm.
Seite 16
STEP 3.6 : Pre-drill the marked holes (b) and screw the assembled bracket into the recess with the M4 countersunk screws (c). Unscrew the U-bracket (a) from the mounting bracket. Insert the power supply cable through the cable entry in the base profile, push the base profile into the opening against the mounting bracket and fix with the M6x35 Allen screw (d).
Seite 17
STEP 3.7 : The sides of the basic profile end in a stair shape (a). The space here, between the profile and the ceiling, must be filled with a filler or sealant (c) and a spatula (b). The countersunk screw heads can also be treated in this way. Finish with paint and roller.
Seite 18
Extra informatie met betrekking tot de montage kunt u vinden op de webpagina in de ZIP file : "General_mounting_instructions_different_languages.zip" via de link : https://www.multiline.be/nl/service/downloads Des informations supplémentaires concernant le montage sont disponibles sur la page Web dans le fichier ZIP : Additionnel "General_mounting_instructions_different_languages.zip"...