Herunterladen Inhalt Inhalt Diese Seite drucken

Automatic Disconnection In Case Of Overload - HomeMatic IP HmIP-PS-2 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Troubleshooting
comes to an end. Homematic IP devices are designed
and produced with 100% conformity to this regulation.
During normal operation, the duty cycle is not usually
reached. However, repeated and radio-intensive teach-
in processes mean that it may be reached in isolated in-
stances during start-up or initial installation of a system.
If the duty cycle is exceeded, this is indicated by one long
lighting of the device LED (A), and may manifest itself in
the device temporarily working incorrectly. The device
starts working correctly again after a short period (max.
1 hour).
8.3
Automatic disconnection in case of
overload
If the device is overloaded with load currents gre-
ater than 13 A or with loads with more than 3 kW
power, after a short delay time, this leads to the
device's automatic disconnection. The safety dis-
connection is reported with an error message via
the app or WebUI.
To be able to use the device again, you must remove the
overload and unplug the device once from the socket
then plug it back in again. Alternatively, you can wait 30
minutes after removing the overload ("restart lock"). The
device can then be switched on again. The device is not
automatically switched on after the restart lock has ex-
pired.