1. Remove 3 screws①.
2. Pull the holder⑤ with heating element③ and steel tube② out of
the handle⑥.
3. Disconnect the yellow and orange cables from the heating
element③.
4. Remove the screw on the steel pipe②.
5. Disconnect green ground wire from steel pipe②.
6. Pull out steel pipe②.
7. Check the holder⑤ for damage.
8. Detach heater insert③ from plug④.
9. Remove heating element③.
10. Install new heating element.
11. Insert plug into holder and slide steel pipe over it.
12. connect green ground wire and screw on.
13. push everything back into the handle and fasten with 3 screws.
14. perform the following test:
15. Perform calibration.