Herunterladen Inhalt Inhalt Diese Seite drucken

After-Sales Service And Application Service - Bosch GAS 35 L AFC Professional Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für GAS 35 L AFC Professional:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 8
OBJ_BUCH-1746-004.book Page 21 Friday, September 15, 2017 12:45 PM
Problem
The vacuum turbine does not start.
Vacuum turbine switches off.
Vacuum turbine does not restart after emptying
the container.
Vacuuming power decreases.
Dust escapes during vacuuming
The automatic shut-off (wet vacuuming) does
not respond.
Automatic filter cleaning inoperative.
The automatic filter cleaning cannot be
switched off.
The automatic filter cleaning cannot be
switched off.

After-sales Service and Application Service

Our after-sales service responds to your questions concern-
ing maintenance and repair of your product as well as spare
parts. Exploded views and information on spare parts can al-
so be found under:
www.bosch-pt.com
Bosch's application service team will gladly answer questions
concerning our products and their accessories.
In all correspondence and spare parts orders, please always
include the 10-digit article number given on the nameplate of
the product.
Great Britain
Robert Bosch Ltd. (B.S.C.)
P.O. Box 98
Broadwater Park
North Orbital Road
Denham
Uxbridge
UB 9 5HJ
At www.bosch-pt.co.uk you can order spare parts or arrange
the collection of a product in need of servicing or repair.
Tel. Service: (0344) 7360109
E-Mail: boschservicecentre@bosch.com
Bosch Power Tools
Corrective Measure
– Check mains cable, mains plug, fuse, socket outlet and filling-level sensors
35.
Mode selector switch 6 set to "Start/Stop automatic".
– Set mode selector switch 6 to the "vacuum" symbol and switch the power
tool connected to the socket outlet 4 on.
– Empty container 1.
– Switch vacuum cleaner off and wait 5 seconds; switch on again after 5 sec-
onds.
– Clean level indicators 35 as well as the space between the level indicators
35 with a brush.
– Remove clogs from vacuum nozzle, vacuum tubes 29, vacuum hose 21 or
flat-fold filter 24.
– Replace disposal bag 23 or dust bag.
– Engage filter cover 34 properly.
– Mount vacuum cleaner lid 10 properly and lock latches 11.
– Replace flat-fold filter 24.
– Check proper installation of the flat-fold filter 24.
– Replace flat-fold filter 24.
– Clean level indicators 35 as well as the space between the level indicators
35 with a brush.
The automatic shut-off does not function with non-conductive liquids or
foam/bubbles.
– Monitor the level continuously.
– Activate the filter cleaning (actuate the AFC button 3).
– Connect the vacuum hose 21.
– Contact an authorised service agent for Bosch power tools.
– Contact an authorised service agent for Bosch power tools.
Ireland
Origo Ltd.
Unit 23 Magna Drive
Magna Business Park
City West
Dublin 24
Tel. Service: (01) 4666700
Fax: (01) 4666888
Australia, New Zealand and Pacific Islands
Robert Bosch Australia Pty. Ltd.
Power Tools
Locked Bag 66
Clayton South VIC 3169
Customer Contact Center
Inside Australia:
Phone: (01300) 307044
Fax: (01300) 307045
Inside New Zealand:
Phone: (0800) 543353
Fax: (0800) 428570
English | 21
1 609 92A 3VZ | (15.9.17)

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

3 601 jc3 23 601 jc3 270

Inhaltsverzeichnis