OBJ_BUCH-1746-004.book Page 20 Friday, September 15, 2017 12:45 PM
20 | English
The filter cleaning system must be actuated at the latest when
the vacuuming performance is no longer sufficient.
Regular use of the filter cleaning feature increases the tool life
of the filter.
To achieve ideal filter tool life, deactivate the automatic filter
cleaning in exceptional cases, e. g., when vacuuming pure liq-
uids or when working with a paper filter bag.
A flat-fold filter contaminated only on the surface is fully func-
tional. Manual cleaning of the flat-fold filter by striking/tap-
ping against it or blowing it out is not necessary, and can even
damage the filter.
Note: The automatic filter cleaning is factory-set.
Switching the automatic filter cleaning on/off is only possible,
when the VAC is running.
– Deactivating the AFC
Actuate the AFC button 3.
The signalling LED 33 goes out.
– Activating the AFC
Actuate the AFC button 3.
The signalling LED 33 lights up green.
Maintenance and Service
Maintenance and Cleaning
Before any work on the vacuum cleaner itself, pull the
mains plug.
For safe and proper working, always keep the vacuum
cleaner and ventilation slots clean.
Wear a dust protection mask when maintaining and
cleaning the vacuum cleaner.
If the replacement of the supply cord is necessary, this has to
be done by Bosch or an authorized Bosch service agent in or-
der to avoid a safety hazard.
A dust-technical inspection is to be carried out at least once
every year by the manufacturer or an instructed person, e. g.
for damage of the filter, tightness against leakage of the vacu-
um cleaner and function of the control/monitoring unit.
For category L vacuum cleaners that were in contaminated
environments, the exterior as well as all machine parts should
be cleaned or treated with sealants. When performing mainte-
nance and repair work, all contaminated components that
cannot be cleaned to satisfactory must be disposed of. Such
components must be disposed of in impermeable plastic bags
conforming with the valid regulations for the disposal of such
waste.
For maintenance on behalf of the user, the vacuum cleaner
must be disassembled, cleaned and maintained as far as fea-
sible, without causing a risk for the maintenance personnel or
other persons. Prior to disassembly, the vacuum cleaner
should be cleaned in order to prevent any risks. The room/en-
closure in which the vacuum cleaner is disassembled should
be well ventilated. Wear personal protective equipment dur-
ing maintenance. After the maintenance, the maintenance ar-
ea should be cleaned.
1 609 92A 3VZ | (15.9.17)
Removing/Replacing the Flat-fold Filter
(see figures I1 – I2)
Replace a damaged flat-fold filter 24 immediately.
– Pull the locking latch 16 and open the filter cover 34.
– Grasp the flat-fold filter 24 by the fins, pull up and remove.
– When taking out the flat-fold filter 24, remove any accumu-
lating dust and debris from the closing edge of the filter
cover 34 using a moist cloth.
PES and PTFE flat-fold filters can be flushed out under run-
ning water.
– Insert a new or the cleaned flat-fold filter 24; observe prop-
er and tight seating.
– Shut the filter cover 34 again (must be heard to engage).
Container
Wipe out the container 1 from time to time with a commercial-
ly available, non-scouring cleaning agent and allow to dry.
Level Sensors (see figure J)
Clean the level sensors 35 occasionally.
– Unlock the latches 11 and remove the vacuum lid 10.
– Clean the level sensors 35 with a soft cloth.
– Reattach the vacuum lid 10 again and lock the latches 11.
Storage and Transport (see figure K)
– Wind the mains cable around the cable holder 15.
– Insert the accessories into the holders provided: Vacuum
tubes 29 in holders 17, crevice nozzle 25 in holder 18,
floor nozzle 28 in holder 19.
– Undue the elastic tie-downs of the vacuum-hose holders 5
and place the vacuum hose 21 around the vacuum cleaner
lid into the holders 5.
Reattach the elastic tie-downs.
– Mount the L-Boxx onto the retainers 9.
– To prevent back injuries, remove a full disposal bag or dust
bag, or drain vacuumed-up fluids before transporting the
vacuum cleaner.
Carry the vacuum cleaner only by the carrying handle 8.
– Store the vacuum cleaner in a dry room and secure it
against unauthorised use.
– To lock the castors 14, actuate the castor brakes 13 by
pushing down.
Correction of Malfunctions
If a fault (e.g. a filter damage) occurs, the vacuum
cleaner must be switched off immediately. The fault
must be repaired before resuming operation.
Bosch Power Tools