Herunterladen Inhalt Inhalt Diese Seite drucken

Specification Measurement Cables; Oscilloscope - Bosch FSA 500 Originalbetriebsanleitung

Fahrzeug-system-analyse
Vorschau ausblenden Andere Handbücher für FSA 500:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
en
| 30 | FSA 500 | Technical data
8.10.3

Specification measurement cables

Designation
Order number
Battery B+/B– cable
1 684 460 286
Clip-on sensor
1 687 225 018
Primary connection
1 684 461 185
cable, term. 1/15
CH1 multi measurement
1 684 460 288
cable
CH2 multi measurement
1 684 460 289
cable
Amps clamp 1000 A
1 687 225 019
Amps clamp 30 A
1 687 225 020
Test prods set:
1 687 016 118
Test prods
Test terminals
Secondary measuring
1 687 225 017
sensor
1 687 225 021
Oil temperature sensor
1 687 230 068
Connection at the input secondary measuring sensor
1)
1.6 Vpeak ±30% at 100 mA current change within 200 ns with connection at input clip-on sensor (L/C approx. 136 µH/5 nF)
2)
For voltages >60 V, U[V] x t[ms] ≤ 10000 V/ms applies, e.g. a voltage of 200 V can be applied no longer than 50 ms. The maximum voltage
3)
reduces at frequencies of >1 MHz with 20 dB/decade, e.g. sine 1 MHz maximum peak = 200 V / sine 10 MHz maximum peak = 20 V
Special accessory
4)
8.10.4

Oscilloscope

R
Trigger system
$
Free run (non-triggered run ≥ 1 s)
$
Auto (curve output even without trigger)
$
Auto-Level (as Auto, mid-signal trigger
threshold)
$
Normal (manual trigger threshold, curve output
only with trigger event)
$
Single sequence
R
Trigger edge
$
Edge (pos./neg. on signal)
R
Trigger sources
$
Engine (trigger on cylinder 1. 12 with clip-on
sensor, term. 1, KV sensor)
$
External trigger via term. 1_1 cable or clip-on
sensor
$
CH1 / CH2 multi measurement cable
R
Pre-trigger component
$
0 to 100%, adjustable with mouse
R
Recording modes
$
MaxMin (Peak/Glitchdetect)
$
Interference pulse recording
$
Sample (equidistant sampling)
R
Storage operating and curve output modes
$
Roll mode (single point output) with complete
storage of signals for X deflections ≥ 1 s
$
Legend mode (curve output) with complete
storage of signals for X deflections ≥ 1 ms
$
Normal mode with storage of last 50 curves
displayed for X deflections < 1 ms
|
1 689 989 411
2023-03-24
Measurement
Max. measuring
category
voltage
CAT I
60 V DC/30 V AC/
42 V ACpeak
CAT I
30 kV ACpeak
CAT I
60 V DC/300 V ACpeak
CAT I
60 V DC/200 V ACpeak
CAT I
60 V DC/200 V ACpeak
CAT 1
300 V DC/ACrms
CAT I
300 V DC/ACrms
4)
CAT III
30 V DC/ACpeak
CAT IV
30 V DC/ACpeak
CAT I
30 kV ACpeak
4)
CAT I
5 V
R
Quantity measurement system with 8 automatic
measurement functions
$
$
$
$
$
$
$
$
R
Selectable signal range
$
R
Zoom
$
R
Adjustable cursors with indicators for
$
$
$
$
R
Comparison curves
$
R
Storage functions
$
$
Sensor output
sensitivity
2)
3)
3)
3)
100 mV/A
4 mV/A
20 mV/kV
1)
Resistance:
1005 Ω at 25 °C
1530 Ω at 90 °C
Mean value
Rms value
Min
Max
Peak-to-peak
Pulse
Duty cycle
Frequency
Full curve or between cursors
Selectable curve section for horizontal and
vertical enlargement
x1, x2
delta x
y1 and y2 (channel 1)
y1 and y2 (channel 2)
Store, load, comment, presetting of scope setup
for live curves
Scrolling back and forth
Search functions, e.g. MinMax, duty cycle
Max. output voltage
at the measurement
cable
60 V
5 V
300 V
200 V
200 V
5 V
5 V
30 V
300 V
1 V
5 V
Robert Bosch GmbH

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis