OPERATION
The pump has no integrated switching on
and off device. As soon as the pump is
connected to the power supply, the pump
starts up.
Automatic mode
The use of OASE ProMax Garden Auto-
matic Switch allows automatic operation.
When the connected appliance (water
withdrawal) is opened, the pump switches
on; when it is closed, the pump is switched
off.
14
Starting up the pump
W A R N I N G
Dangerous electrical voltage!
Death or severe injury from electrocu-
tion.
• Only connect the pump to the power
supply when there are no persons in or
reaching into the water.
• Before stepping into or reaching into the
water, switch off all units located in the
water.
• Insert the power plug into the socket.
– The pump starts pumping.
N O T E
If the water contains a large quantity of
suspended sand (e.g. in the case of a
new well), allow the pump to run at full
flow rate for approx. 1 hour without inter-
ruption in order to pump out the water
containing the sand. Otherwise the non-
return valve could become blocked by
sand being deposited in the pressure
line.
Taking the pump out of operation
• Disconnect the power plug.
– When the pump is switched off, resid-
ual water in the hose may flow back
and out of the pump intake.