Activate the self priming and wait a reasonable amount of time for this to be
completed.
5. MAINTENANCE
Clean the pre filter basket regularly to avoid drops in pressure. TO prevent the basket
from breaking, do not hit it during the cleaning process.
Should the pump stop, check that the consumption of the running motor in amperes is
equal to or below that indicated on the manufacturer's characteristics plate. If this
information is not available, contact the nearest Technical Assistance Service.
Where the amperage is higher, consult the manufacturer.
Empty the pump if it is to remain at a standstill for a certain length of time, especially in
cold countries where there is a risk of freezing.
Remove the purge cap (10) to empty the pump.
Every time the pre filter is opened, clean the seal and its seating of any impurities to
ensure air tightness when the cap is closed (Fig. 5).
Pump components that, due to their normal use, suffer wear and/or tear must be
regularly replaced to ensure good pump performance. The following table shows the
perishables and/or consumables used in the pump and their estimated working life.
COMPONENT DESCRIPTION
0 rings and general seals
The estimated working life of the parts above has been established according to the normal product
use and installation conditions.
Follow the instructions in the installation manual to maintain the working life of the pump.
6. REMOVAL
The motor unit can be removed from the pump body without having to disconnect the
pump's suction and return pipes.
To remove the Motor unit from the pump body, remove the screws joining them
together.
7. TROUBLESHOOTING
1. The pump is not primed
2. The pump releases only a small flow of water
3. The pump makes a noise
Installation and General Maintenance Manual – Viron P300 Pool Pump
All manuals and user guides at all-guides.com
Mechanical Seal
Bearings
4. The pump will not start
5. The motor is making a noise but will not start
6. The motor is stopped
ESTIMATED WORKING LIFE
1 year
1 year
1 year
9