Product Safety Information
Intended Use:
These Air Sump Pumps are designed for pumping non-hazardous liquids that are compatible with
pump components.
For additional information refer to Air Sump Pump Product Safety Information Manual Form 16576597.
Manuals can be downloaded from www.irtools.com.
Product Specifications
Size of Opening Pump
will Pass Through
Model
inch
P237A1-EU
8-3/4 X 8-3/4
P237A3-EU
8-3/4 X 8-3/4
† tested in accordance with ANSI S5.1 - 1971 at 100 feet (30.5 m) of head
(approximately 43.5 psig [3.0 bar/300kPa]) back pressure.
Installation and Lubrication
Size air supply line to ensure tool's maximum operating pressure (PMAX) at tool inlet. Drain condensate from
valve(s) at low point(s) of piping, air filter and compressor tank daily. Install a properly sized Safety Air Fuse
upstream of hose and use an anti-whip device across any hose coupling without internal shut-off, to prevent
hose whipping if a hose fails or coupling disconnects. See drawing 16586117 and table on page 2.
Maintenance frequency is shown in circular arrow and defined as h=hours, d=days, and m=months. Items
identified as:
1.
Air filter
2.
Regulator
3.
Lubricator
4.
Emergency shut-off valve
5.
Hose diameter
6.
Air Inlet - Thread size
7.
Safety air fuse
Adjustments
Air Strainer
Periodically, clean the Air Strainer Screen as follows:
1.
Shut off the air supply to the pump.
2.
Unscrew the Air Strainer Cap and remove the Air Strainer Screen.
3.
Clean the Screen in a suitable cleaning solution.
04585154_ed1
Pump
Housing
Material
mm
222 x 222
Iron
222 x 222
Iron
8.
Oil
9.
Oil - If Lubricator (3) is not used
10. Oil - Fill oil chamber before initial start
11. Grease - In fitting
12. Air Exhaust - Thread size
13. Pump Discharge - Thread size
Sound Level dB (A)
Piped Away
Non-Piped Away Exhaust
Exhaust
† Pressure
† Pressure
74.9
104.4
74.9
104.4
EN
Power
(ISO3744)
117.4
117.4
EN-1