EUROSTER 506 – USER MANUAL
INTRODUCTION :
The unique design of this product includes "Intelligent Mode Selection"
which allows selecting the desired operation mode either heating/cooling or floor-heating.
There are 3 operating modes :
1. Room mode - Room sensor commands.
Room temperature regulation either for cooling or heating.
2. Floor mode (Floor heating) - Floor sensor commands.
Floor temperature controls heating.
3. Room + Floor limitation (Floor heating) - both Room sensor & Floor sensor joint command
Room temperature as the priority command to heating system with floor temperature limitation.
Thermostat can detect from the jumpers
1. The number of temperature sensors that have been connected.
2. If the Cooling or Heating mode is required
The unit will automatically operate in the mode that has been detected.
Factory default settings: Heating & room-sensor enabled.
Choosing correct location for the thermostat :
The thermostat should be located in the room where the heating/cooling is to be controlled, except in case for floor heating only.
The place of installation should be chosen so that the sensors can measure the room temperature as accurately as possible, without
being affected by direct solar radiation or other heating or cooling sources.
The mounting height should be approximate 1.5 meters above the floor.
The unit can be fitted to most commercially available recessed conduit boxes or directly on the wali (Surface-mount box for
installing this unit is also available)
Start installation - lt's important to follow the procedures described in this section, otherwise the thermostat may not work properly.
To open thermostat plastic housing - Refer to photo description below :
Plastic enclosure of this unit consists 3 plastic parts, front, frame and bottom. They are assembled by an unique design of hook-on
closure.
Hook-On clip extends from the Bottom part, through the Frame at middle and hook on to two tiny square holes on both right & left
side of the Front part of the plastic housing.
8
EUROSTER 506
Insert
screw driver
into square
hole on one
side
Tilt upward
to loosen
the front part
from hook-on
elips.
Tilt
screw driver
upward to
loosen.
Open by
hands, as
shown on
left