Herunterladen Inhalt Inhalt Diese Seite drucken

Possible Options For The Unit - Daikin LMS Serie Installationsanleitung

Vorschau ausblenden Andere Handbücher für LMS Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 30
4 About the unit and options
a
b
a
Primary unit
b
Secondary unit
The main PCB allows easy parallel connection between one primary
unit and the secondary units.
a
c
b
b
a
Primary unit
b
Secondary unit
c
Router (option)
The primary unit performs all monitoring and control functions.
The system can be connected to the internet through the router
(optional).
To install connections and set parameters, see "5.6.1  To install
multiple units" [ 4  14].
4.5

Possible options for the unit

INFORMATION
Certain options may NOT be available in your country.
Three cable glands (a, b and c) are provided to bring the option
cables into the unit.
a
Option
b
Option
c
Option
d
Door heater, pre-wired (5 m)
e
Power supply, pre-wired (5 m)
f
Door micro switch, pre-wired (5 m)
Installation manual
8
b
b
b
b
b
a b
c
d
e f
Insulation pad
The insulation pad is mandatory for wall installation. See "5.4.2  To
prepare the cold room" [ 4  11].
a
b
c
d
d
a
Flat washer (×2)
b
Spring washer (×2)
c
Metric bolt M8 (×2)
d
self-adhesive gasket
e
Insulation pad assembly
Door microswitch
To reduce frost on the evaporator, the door microswitch interrupts
the unit operation when the cold room door is open. It also controls
the cold room lamp. The door microswitch is an accessory. See
"5.7.1 To install the door microswitch" [ 4  15].
Door heater
For low temperature applications it is suggested to install a door
heater. It prevents the door from freezing. The choice for the most
appropriate door heater is left to the installer or cold room
manufacturer. Sometimes the door heater is already included in the
pre-fabricated door kit. See "5.7.3 To install the door heater" [ 4  16].
INFORMATION
The door heater accessory is only necessary for low
temperature applications.
Cold room lamp
The lamp is ON when the cold room door is open. It is controlled by
the user interface. The cold room lamp is an accessory. See
"5.7.2 To install the cold room lamp" [ 4  15].
INFORMATION
As there are only 3 free cable glands, only 3 more options
can be installed.
Alarm
An alarm feature can be installed (light or sound). See "5.8  To
connect an alarm signal" [ 4  16].
Router
The unit (or multiple units) can be connected to the internet through
a router, available as an option. See "5.9  To connect a
router" [ 4  17].
Combining multiple units
To interconnect multiple units, a communication cable must be used.
See "5.6.1 To install multiple units" [ 4  14].
LMSEY1A09/13 + LMSEY2A19/25
Daikin LMS
4P728170-1B – 2023.07

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis