 the evaporation and condensation pressure values at the time of the alarm;
 alarm delay time from the switch-on of the connected device;
 compressor status at the time of the alarm;
o Advanced functions:
 Pump Energy-Saving management;
 evaporator pump control KPE, contactor recovery pump command KPR and KPDS desuperheater Pump Control in the case of external supply of elec-
tric pumps (to be installed by the installer). For the unit to operate properly, activation of the recovery pump, by the installer, must be controlled by
means of a specific discrete output provided in the board on the unit;
 High-Pressure Prevent function with forced cooling capacity partialisation for a high outdoor temperature (in summer mode);
 the EEO - Energy Efficiency Optimizer function allows unit efficiency to be optimised by acting on the electrical absorption, thereby minimising con-
sumption. The algorithm identifies the optimal point that minimises the total absorbed power (compressors+fans) of the unit by actuating the fan rotation
speed.
 VPF_R control: (Variable Primary Flow by HITECSA in the main exchanger). VPF_R includes the temperature probs, the inverter management and
the management software of the chiller;
 set-up for serial connection (SS/KRS485, FTT10/KFTT10, BE/KBE, BM/KBM, KUSB accessory);
 possibility to have a digital input for remote management of double set point (DSP);
 possibility of having a discrete input for total recovery management (RC100 contact), the desuperheater (CDS contact) or for the production of domestic
hot water by means of a 3-way diverter valve (CACS contact). In this case, there is the possibility of using a temperature probe instead of the discrete
input. (refer to the specific section for more details);
 option of having domestic hot water diverter valve (VACS) control;
 possibility to have an analogue input for the shifting Set-point (CS) via a 4-20mA remote signal;
 management of time bands and operation parameters with the possibility of daily/weekly functioning programs;
 check-up and monitoring of scheduled maintenance status;
 computer-assisted unit testing;
 self-diagnosis with continuous monitoring of the unit functioning status.
 MASTER/SLAVE management logic integrated in single systems (SIR - Sequenziatore Integrato HITECSA - HITECSA Integrated Sequencer) -Refer
to the specific section for more details
o Set-point regulation via the AdaptiveFunction Plus with two options:
 fixed set-point (Precision option);
 set-point sliding (Economy option).
2.2. ACCESSORIES

Factory Fitted Accessories

Installation with pump
P1
Installation with a pump on the RC100 recovery circuit
PR1
Installation with increased static pressure pump
P2
Installation with an increased head pump on the RC100 recovery circuit
PR2
Installation with double pump, including an automatically activated pump in stand-by
DP1
Installation with a double pump, including one automatically activated in standby on the RC100 recovery circuit
DPR1
Installation with increased static pressure double pump, including an automatically activated pump in stand-by
DP2
Installation with increased head double pump, including an automatically activated pump in standby on the RC100 recovery circuit
DPR2
Installation with pump and storage tank
ASP1
Installation with double pump, including an automatically activated pump in standby and storage tank
ASDP1
Installation with an increased head pump and storage tank
ASP2
Installation with and increased head double pump, including an automatically activated pump in standby and storage tank
ASDP2
Compressor aphonic ear muffs
CAC
Soundproof compressor box
BCI
Soundproofed compressor box with high acoustic impedance material (standard for EQRUSS-EQRHUSS)
BCIP
Cooling circuit intake and flow taps (only EQRU-EQRUSS)
RS
Cooling circuit outlet valves (only EQRHU-EQRHUSS)
RM
Desuperheater.
DS
IOM_EQRU-SS_EQRHU-SS_2160a4350_208676_230601_ES-EN-FR-DE-IT
73
Compressor consumed power
Pac
Pav Fan consumed power
Total absorbed power
Pt
Absorbed power
Pa
Condensation pressure
Hp
EQRU-EQRUSS
EQRHU-EQRHUSS