Ducted version air exhaust system Connection
When installing the ducted version, connect the
hood to the chimney using either a flexible or rigid
pipe ø 150 or 120 mm, the choice of which is left to
the installer.
• To install a ø 120 mm air exhaust connection,
insert the reducer flange 9 on the hood body out-
let.
• Fix the pipe using the pipe clamps 25 (not pro-
vided).
• Remove any activated charcoal filters.
RECIRCULATION VERSION AIR OUTLET
• Insert the reducer flange 9 on the air outlet of the
extractor.
• Attach the adhesive Novastik gasket 13 to the air
outlet connection 15 and fix this to the upper
frame using the 2 knobs 24.
• Fix the air outlet connection extension piece 14
to the air outlet connection 15.
• Connect the hood air outlet to the flange in the
lower part of the junction using a rigid or flexible
ø 120 tube (by installer's choice).
EN
ø 150
25
15
14
ø 120
25
9
24
15
15
14
9
1
11