Herunterladen Inhalt Inhalt Diese Seite drucken

Continuity Check; Capacitance Measurement; Temperature Measurement - Multimetrix CM604 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 22
plug into the + terminal.
„ Touch the test lead probes to the diode under test.
„ Forward voltage will indicate 0.4 to 0.7V on the LCD display; Reverse voltage will indicate OL; Shorted
devices will indicate near 0 and an open device will indicate OL in both polarities.

4.5. CONTINUITY CHECK

WARNING: Never test continuity on a live circuit.
„ Set the rotary switch to the
„ Press the MODE button until the
„ Insert the black test lead banana plug into the negative COM terminal; Insert the red test lead banana
plug into the + terminal.
„ Touch the test lead probes to the device or wire under test.
„ A beeper will sound if the resistance is approx. 50 Ω or less and the resistance reading will be shown
on the LCD display.

4.6. CAPACITANCE MEASUREMENT

WARNING: To avoid electric shock, disconnect power, remove the batteries and unplug the line cords
of the unit under test. Discharge all capacitors before taking any capacitance measurements.
„ Set the rotary switch to the
„ Press the MODE button until the nF symbol appears on the LCD display.
„ Insert the black test lead banana plug into the negative COM terminal; Insert the red test lead banana
plug into the + terminal.
„ Touch the test leads to the capacitor to be tested. Wait until the readings settle before ending the test.
„ Read the capacitance value in the display.

4.7. TEMPERATURE MEASUREMENT

WARNING: Do not touch the temperature probe to live circuits.
„ Set the function switch to the Temp position.
„ Press the MODE button to indicate °C or °F.
„ Connect the temperature probe to the banana plug adapter, note the - and + markings on the adapter.
„ Connect the adapter to the clamp meter, making sure the - side goes into the COM terminal and the
positive side goes into the + terminal.
„ Touch the tip of the temperature probe to the object being measured.
„ Read the temperature on the LCD display.
position.
symbol appears on the LCD display.