Technical data

Problem
The display shows
"Error 30"
The display shows
"Error 35"
The display shows
"Error 40"
12
Technical data
Item number:
Dimensions (width x height x depth)
Weight:
Power supply:
Refrigerant extraction rate:
Vacuum pump output:
Hermetic compressor output:
Drier filter output:
Filling cylinder accumulator capacity:
Noise emission:
Accuracy of the electronic scale for refrigerant:
Accuracy of the electronic scale for old/new oil:
Accuracy of the electronic scale for UV additive:
Operating temperature range:
128
Cause
Pressure drop during leak
test.
Residual pressure in the air
conditioning system.
Pressure drop during
pressure test.
ASC5000RPA/ASC5500RPA
Remedy
Check unit for leaks.
Drain and evacuate.
Check air conditioning
system and connections for
leaks.
AirConServiceCenter
ASC5000RPA, ASC5500RPA
9103301870
560 mm x 1300 mm x 650 mm
100 kg
230 V/240 V–50 Hz/60 Hz
30 kg / hr
5 cars / hr
0.32 kW
150 kg
16 kg
55.5 dB (A)
± 10 g
± 1 g
± 1 g
+ 5 °C to + 50 °C
EN