ATTENTION!
Pressure surge damage!
If the medium enters strongly heated, empty collectors, pressure
surges can occur.
Î Do not fill or flush the system during times of strong
irradiation!
ATTENTION!
Damage through overheating!
Fluid temperatures of more than 65 °C can lead to pump damage.
Î Make sure that the fluid temperature does not exceed
65 °C.
ATTENTION!
Damage through dry run!
Dry run of the pump can lead to destruction of the pump.
Î Make sure the pump does not operate in dry run con-
dition!
ATTENTION!
Damage to the device through overheating!
During operation, the pump motor can reach a temperature of
up to 70 °C.
Î Make sure the air supply for motor cooling is not
blocked!
1.2
Notes on transport and storage
ATTENTION!
Damage through freezing!
Freezing can lead to damage of the filling and flushing station!
Î Make sure the station is stored in a frost-protected
place.
Î Make the pump does not contain any fluid.
Note
Only transport the filling and flushing station in a horizontal position and
when it is empty.
2
Electrical connection
The cross-section of the connection cable must be at least 1.5 mm².
Note
For your own safety: only use the filling and flushing station in an electri-
cal circuit fused by a residual current device.
3
Connection examples
Flushing hose
Pressure
hose
Filling and flushing station
Filling and flushing unit
15