Oil burner
TECHNICAL FEATURES
Thermal power – output
Fuel
Electrical supply
Motor
Capacitor
Ignition transformer
Pump
Absorbed electrical power
For use on hot air generator the burner must be fitted with control box type 479SE or 539SE.
Burner with CE marking in conformity with EEC directives: EMC89/336/EEC, Low Voltage 73/23/EEC,
Machines 98/37/EEC and Efficiency 92/42/EEC.
The burner meets protection level of IP 40, EN 60529.
CE Certification No. : 0036 0258/99 as 92/42/EEC.
1 – Return line
2 – Suction line
3 – Gauge connection
4 – Pressure regulator, 2
5 – Vacuum gauge connection
6 – Hydraulic jacks with air-damper
7 – Combustion head adjustment screw
8 – Lock-out lamp and reset button
9 – Flange with insulating gasket
10 – Regulation pressure, 1
11 – Economizer
2352
All manuals and user guides at all-guides.com
G10 I
CODE
44 / 54 – 120 kW
Gas oil, max. viscosity at 20 ° C: 6 mm
Single phase, 230 V ± 10%
Run current 0.80 A – 2785 rpm – 292 rad/s
4 m F
Secondary 8 kV – 16 mA
Pressure: 7 – 15 bar
0.17 kW
S7349
nd
stage
st
stage
3746613
–
3.7 / 4.5 – 10 kg/h
~
Fig. 1
EQUIPMENT
Quantity
2
Flexible pipes with nipples
1
Flange with insulating gasket
4
Screws and nuts for flange
1
Hinge
1
Screw with two nuts for flange
1
External probe
1
7 pin plug
1
4 pin plug
1
GB
466T1
TYPE
/s (1.5 ° E)
2
50Hz
Description