Anleitung_BT_BC_30_SPK1__ 06.06.13 14:42 Seite 16
GB
10. Troubleshooting
If the equipment is operated properly you should experience no problems with malfunctions or faults. In the
event of any malfunctions or faults, please check the following before you contact your customer services.
Fault
Overload cut-out trips
Charging current indicators does
not work
16
Possible cause
- Charger clamps connected
incorrectly
- Contact between the charger
clamps
- Battery highly discharged
- Battery defective
- Poor contact between the
charger clamps and battery
poles
- Battery defective
- Defective charging current
indicator
Remedy
- Connect the red clamp to the
positive pole and the back clamp
to the bodywork
- Prevent contact
- Select a lower charging current
- Have the battery checked by an
expert and replace it if necessary
- Clean the contacts and charger
clamps
- Have the battery checked by an
expert and replace it if necessary
- Check the function of the
equipment using a different
battery