Live components may be exposed if covers are opened or parts
are removed unless this can be done by hand. The connection
points may also be live. Before calibration, servicing, repair work
or the replacement of parts or assemblies, the device must be dis-
connected from all sources of current if it has to be opened. If
after that, calibration, servicing or repairs on the open device are
unavoidable, these may only be carried out by a specialist who is
familiar with the risks involved and with the relevant regulations.
Capacitors in the device may still be charged even if the device
has been disconnected from all sources of voltage and measuring
circuits.
Servicing
The PC oscilloscope is maintenance-free except for occasional cleaning
with a clean, fuzz-free, anti-static, dry cleaning cloth.
Do not use scouring or chemical agents containing petrol, alcohol
or similar substances for cleaning purposes. These could attack
the surface. Moreover, the vapours are detrimental to health and
also explosive.
Never use sharp-edged tools, screwdrivers, metal brushes or sim-
ilar for cleaning.
Technical data / specifications
Oscilloscope
DSO-220 USB
Time distraction
50 ns to 0,5 s/Div
Input sensitivity:
50 mV to 5 V/div in 7 steps in position 1:1 (probe head)
500 mV to 50 V/div in 7 steps in position 10:1
Trigger queue
Channel 1 = CH1 or channel 2 = CH2 or external
Trigger flank = slope
Trigger level
Dot interpolation
Storage depth
Vertical mode
X-Y mode
AUTO setup
Yes (30Hz bis 5 MHz)
38
DSO-2100 USB
5 ns to 1 h/Div
positive (rising flank) or negative
(descending flank)
Automatic
Linear or staircase form
32 kB/channel
CH1, CH2, Dual, ADD
Yes
Yes (30Hz bis 30MHz)
Any other use than that described above can lead to damage to the product and may
involve other risks such as short circuits, fire, electrical shocks etc.
The safety instructions must be observed at all times!
Safety instructions
Please read the operating instructions through fully before setting
up the device; they include important information for correct
operation.
The guarantee will lapse in case of damage caused by failure to
comply with these operating instructions! We shall not be liable
for any consequent damage!
We do not take any responsibility for personal injury and damage
to property caused by incorrect handling or non-observance of
the safety instructions! The guarantee will lapse in these cases.
This device left the works in a perfectly safe condition.
To maintain this status and ensure safe operation, the user must observe the safety
instructions and warnings ("Caution!" and "Note!") contained in these instructions for
use. The following symbols are to be observed:
= Note! Read the instructions for use.
= This product is CE-tested and meets the necessary directives.
For safety and licensing (CE) reasons, unauthorised conversion and/or modification
to the product are not permitted.
Consult a specialist if you have doubts about how the equipment operates, its safe-
ty or its connection.
Also observe the safety and operating instructions of any other appliances which are
connected to the device as well as to the individual section of these instructions.
Keep the device out of the reach of children. It is not a toy.
23