22. Correction of Malfunctions

Problem
The material is
suctioned at the
first filling, but does
not feed through
the hose, or only in
intervals
No coating material
emerges from the
nozzle
Coating material drips
from the nozzle
Atomisation too
coarse
52
52
Cause
There is a kink in the material
hose
The material is too thick and is
blocking the hose
Nozzle clogged
Material volume too large
Container empty
Suction hose is blocked
The suction hose is not in the
paint
The pressure reducer is
clogged up
Pump is defect
Nozzle loose
Nozzle worn
Nozzle seal is missing or worn
Coating material assembly at
air cap, nozzle or needle
Coating material too thick
Material volume too large
Nozzle contaminated
Air filter heavily soiled
Amount of air too low
WallPerfect Flexio 990
WallPerfect Flexio 990
Remedy
Remove kink
Follow the instructions in
chapter 20 until the spray
attachment is hooked
over the paint container
(Fig. 25). Next, switch on
the pump and leave it
running until the material
emerges evenly (this can
take several minutes).
Thin the material as
required. Continue with
the start-up operation in
chapter 10.
➞ Clean
➞ Reduce material volume
➞ New paint container
➞ Clean suction hose
➞ Immerse the suction
hose
➞ Reduce the pressure
and clean the pressure
reducer (fig. 26-28)
➞ Please contact Wagner
Service
➞ Tighten the union nut
➞ Change
➞ Insert an intact nozzle
seal
➞ Clean
➞ Dilute
➞ Reduce material volume
➞ Clean
➞ Change
➞ Increase air volume