GB
D
22. Correction of Malfunctions
Problem
The material is
suctioned at the
first filling, but does
not feed through
the hose, or only in
intervals
No coating material
emerges from the
nozzle
Coating material drips
from the nozzle
Atomisation too
coarse
52
52
Cause
•
There is a kink in the material
hose
•
The material is too thick and is
blocking the hose
•
Nozzle clogged
•
Material volume too large
•
Container empty
•
Suction hose is blocked
•
The suction hose is not in the
paint
•
The pressure reducer is
clogged up
•
Pump is defect
•
Nozzle loose
•
Nozzle worn
•
Nozzle seal is missing or worn
•
Coating material assembly at
air cap, nozzle or needle
•
Coating material too thick
•
Material volume too large
•
Nozzle contaminated
•
Air filter heavily soiled
•
Amount of air too low
WallPerfect Flexio 990
WallPerfect Flexio 990
Remedy
•
Remove kink
•
Follow the instructions in
chapter 20 until the spray
attachment is hooked
over the paint container
(Fig. 25). Next, switch on
the pump and leave it
running until the material
emerges evenly (this can
take several minutes).
Thin the material as
required. Continue with
the start-up operation in
chapter 10.
➞ Clean
➞ Reduce material volume
➞ New paint container
➞ Clean suction hose
➞ Immerse the suction
hose
➞ Reduce the pressure
and clean the pressure
reducer (fig. 26-28)
➞ Please contact Wagner
Service
➞ Tighten the union nut
➞ Change
➞ Insert an intact nozzle
seal
➞ Clean
➞ Dilute
➞ Reduce material volume
➞ Clean
➞ Change
➞ Increase air volume