12. Switch on and off of modeling
lamp
1. Switch on device.
See Switch the device on and off.
2. Switch on modeling lamp:
Press control OUTPUT POWER 1x.
• The modeling lamp switches on.
• The LED MODEL lights.
3. Switch off modeling lamp:
Press the OUTPUT POWER key,
until the LED MODEL goes out.
• The LED MODEL goes out.
13. Trigger the flash
WARNING
Fire danger through overheating.
Continuous rapid sequences of flashes
from more than 8 flashes per minute with
high flash output could overheat and dama-
ge the device. Heat accumulation could be
the result when using small, narrow reflec-
tors (e.g. snoots) or grid reflectors at high
power with the device pointing downwards.
Continuous increasing and decreasing of
the flash output can heat up the device
additionally.
■ Avoid continuous rapid sequences of
flashes from more than 8 flashes per
minute with high flash output.
■ Don´t use the device in vertical direc-
tion, when making rapid flash sequen-
ces and high flash output with a small,
narrow reflector or grid reflector.
■ Don´t increase and decrease the output
unnecessary.
■ Note the following mentioned restrictions.
36
1. Switch on device.
See Switch the device on and off.
2. Modeling lamp is switched on and off
according to requirements.
See Switch the modeling lamp on and off.
3. Trigger flash according to the prepared
type of flash trigger.
See Prepare and adjust flash trigger.
• Do not flash over 12 shots per minute for
over 10 minutes.
• Do not flash over 10 shots per minute for
over 30 minutes.
• Do not flash over 8 shots per minute for
over 60 minutes.
• In the above mentioned cases, let the
device cool down for at least 15 minutes.
o Don´t switch off the device during the
15 minutes cooling time as to avoid the
interruption of the cooling.
o Don´t trigger a flash during the 15
minutes cooling time, neither with
reduced flash output.
o Switch off the modeling lamp.
See Switch on and off of modeling lamp.
• When the signal warning of overheating
and overloading beeps:
Reduce the flash output or flash sequence.
If the continuous beep don´t stop:
Let the device cool down for at least
30 minutes:
o Don´t switch off the device during the
30 minutes cooling time as to avoid the
interruption of the cooling.
o Don´t trigger a flash during the 30
minutes cooling time, neither with
reduced flash output.
o Switch off the modeling lamp.
See Switch on and off of modeling
lamp.