Herunterladen Inhalt Inhalt Diese Seite drucken

Ventilation Hose And Connection (For Products Equipped With An Outlet Vent) - Beko DA 8012 GA Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

B
DANGER!
Do not place the product on top of the
power cable.
• Keep at least 1.5 cm distance to walls of
other furniture.
3.2 Ventilation hose and connection
(for products equipped with an outlet
vent)
Ventilation hose allows exhaust air from inside
the machine
Vented dryer has 1 air outlet.
Stainless sheet metal or aluminum pipes can
be used instead of a hose. The pipe diameter
should be minimum 10 cm.
Maximum hose and pipe lengths are given in
the table below.
Maximum length
1 elbow 45°
1 elbow 90°
1 elbow 90° short
1 wall passage
C
NOTE
Each elbow and other passages should
be subtracted from the maximum length
stated above.
To connect a ventilation hose;
1.
Connect the air outlet hose to the
hose spacer piece by turning it
counterclockwise.
2.
Make the hose passages as shown
below.
30
Hose
Pipe
4 m
5 m
-1.0 m
-0.3 m
-1.8 m
-0.6 m
-2.7 m
-2.0 m
-2.0 m
C
NOTE
Exhaust of humid air from the dryer
into the room is inconvenient. It may
damage the walls and furniture in the
room.
The ventilation hose can be routed
outdoors via a window or it can be
connected to the air outlet in the
bathroom.
Air outlet hose must be routed directly
to the outdoors. There must be a limited
number of elbows as not to hinder
ventilation.
To prevent water accumulation in the
hose, make sure that it is not folded on
the floor.
B
DANGER!
The ventilation hose should not be
connected to the chimney of a stove or a
fireplace.
Do not operate your product at the same
time with heaters such as a coal or gas
stove. Airflow may cause the chimney to
flare up.
Dryer / User Manual

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis