2.6. If the sauna heater will not heat up

If the sauna heater will not heat up, please check that:
-
the power is on;
-
the main fuses of the sauna heater are intact;
-
is there any error messages on the control panel. In case of an error message on the control panel,
please refer to the control panel instructions.
THE PERSON INSTALLING THE SAUNA HEATER SHOULD LEAVE THESE INSTRUCTIONS AT THE PREMISES
FOR THE FUTURE USER.

2.7. Preparing for sauna heater installation

Check the following before installing the sauna heater.
- The ratio of the heater's input (kW) and the sauna room's volume (m
Table 1 on page 8. The minimum and maximum volumes must not be exceeded.
- The sauna room height must be a min. of 1900 mm.
- Uninsulated and masonry stone walls extend the preheating time. Each square metre of plastered ceiling or wall
3
surface adds 1.2 m
to the sauna room's volume.
- Check page 8 Table 2 for a suitable fuse size (A) and the correct diameter of the power supply cable (mm²) for the
sauna heater in question.
- Conform to the specified safe clearance around the sauna heater. Please refer to page 8.
- There should be enough room around the sauna heater controls for maintenance purposes. Also a doorway can be
considered as a maintenance area.

2.8. Helo Qlick-Fix heater installation

Install the heater in the sauna in accordance with the safety distances in table 1 on page 8. A thin panel is not enough
as a mounting base, the mounting base must be reinforced with a board behind the panel. Table 1 on page 8 1gives
the minimum distances that must be observed, even if the wall material is a non-combustible material.
Walls or ceilings must not be clad with fibre-reinforced plaster board or other light-weight cladding, because they may
cause a fire hazard.
Only one heater may be installed in the sauna.
See table 1 for minimum safety distance to wall B and
floor J. Use mounting paper to locate the holes. Drill a
3.5mm pilot hole in the panel and fasten
6 x 40 mm mounting screws (2 pcs) to the wall. Leave a
gap between the screw head and the wall 1-2 mm. Install
the heater by pushing it into place through the holes and
lowering. The tongues lock the heater, preventing lifting
without a tool.
3
). Volume recommendations are presented in
When performing maintenance, the heater can be removed
from the wall mount if necessary by unscrewing the 4
screws on the sides.
NOTE! Stones must be removed before the heater is
removed. Slide the heater upward and pull it outward.
Reinstall in the reverse order. Press into the slots, lower
and tighten the screws.