MAINTENANCE

Wipe the aperture lens and the body of the cross laser with a clean soft cloth. Do not use solvents.
Although the cross laser is dust and dirt resistant to a certain degree, do not store in dusty places as long
term exposure may damage internal moving parts.
If the cross laser is exposed to water, dry the laser level before returning it to the carrying case to prevent
corrosion damage.

TECHNICAL DATA

Laser class
Self-leveling range
Self-leveling time
Battery technology
Voltage DC
Protection class (water and dust
protection)
Max. altitude
Relativ air humidity max.
Pollution degree according to
IEC 61010-1
Pulse duration t
P
Nornal mode ≤ 80 µs
Power save ≤ 50 µs
Functions
Frequency
Projections
Diode quantity
Diode type
Laser beams output pattern
Operating time
Tripod mount
Suitable detector
ENGLISH
2
± 4°
≤ 3 s
Li-Ion
12 V
IP54*
2000 m
80%
2**
Horizontal level line & horizontal points
Vertical plumb line & plumb points
Perpendicular level, plumb points & horizontal points
10 kHz
2 lines green, 4 points green
2
50 mW
Single horizontal level line + 2 horizontal points (left & right);
Single vertical plumb line + 2 plump points (up & down);
Cross line + 2 horizontal points + 2 plump points.
9 hrs (normal mode) / 16 hrs (power save mode) with M12
3.0 Ah Battery
1/4" / 5/8" thread
Milwaukee LLD50, LRD100
Laser Line
Width < 11.12mm @ 38"
Wavelength 510 - 530 nm laser class II
Max. power ≤ 7 mW
Accuracy +/- 3 mm / 10 m
Beam divergence 1 rad
Fan angle vertical line > 150°; horizontal line > 180°
Colour green
Working range 38 m (with detector LLD50 50 m, with detector LRD100 100 m)
Laser points
Laser point wavelength 510 - 530 nm laser class II
Laser point max. power < 1 mW
Plumb accuracy +/- 3 mm / 10 m
Points beam divergence 0.5 mrad
Laser point colour green
Working range 38 m
Recommended ambient operating
temperature
Storage temperature
Recommended battery types
Dimensions
Weight (incl. battery)
* The Lithium-ion battery and the battery compartment are excluded from IP 54.
** Only non-conductive deposits occur, whereby occasional temporary conductivity caused by
condensation is expected.

SPECIFIC CONDITIONS OF USE

The laser is innovatively designed for a very broad range of professional jobs, including:
- Aligning tiles, marble, cabinets, borders, moldings and trimmings
- Marking layout for doors, windows, rails, stairs, fences, gates, decks and pergolas installation.
- It is intended for determining and checking horizontal and vertical lines.
- Levelling suspended ceilings, Levelling pipe installations, Window partitioning and pipe alignment, laying
out perimeter walls for electric installations.
Do not use this product in any other way as stated for normal use.
-20°C - +40 °C
-20°C - +65 °C
M12 B...
171 x 82 x 150 mm
1262 g
2