Herunterladen Inhalt Inhalt Diese Seite drucken

Dimensions; Basic Length/Weights; Loading Data; Loading Data * Rk Pipe System Linear Unit Light Unit 30 - RK Rose+Krieger Light Unit 30 Montageanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6.3 Dimensions

Linear units are produced individually to length in accordance with your specification.
The width and height of this linear unit is determined from the choice of size and design and can
be taken from the Linear Components catalogue.
6.3.1 Basic lengths/weights
Version
RK pipe system linear unit
Light Unit 30

6.3.2 Loading data

In dynamic operation, this must be considered for the design:

6.3.3 Loading data * RK pipe system linear unit Light Unit 30

Version
Fx
Length overall
in mm
Flexing
RK pipe system linear
unit
300
Light Unit 30
* related to guidance slides (values static, end element supported)
Mx

6.4 Emissions

The A-rated equivalent continuous sound pressure level of these linear units is below 85 dbA.
Basic length in mm
80
Fx max = m * a [m/s2]
Permitted force (N)
Fy
300
500
800
1000
1.0
2.5
4.0
5.0
700
550
270
140
Fy
6. Product information
Weight in kg
basic length
0.097
Fz
300
500
800
1000
1.0
2.5
4.0
1390
1210
600
Fz
My
Mz
Weight in kg
per 100 mm travel
0.099
Permitted torque (Nm)
Mx
My
Mz
1000
1000
1000
5.0
450
2.5
5.5
5.5
Fx
31

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis