Technical Data
16
Welder
Art. No
Degree of protection
Insulation class
Rated input voltage (AC Current) U
Mains frequency
Protection, time delay
No-load voltage U
Idle state power
Efficiency of the Welding Power Source
Load voltage U
2
Welding current I
Switch-on time X *
Regulated section Welding current
Maximum rated input current I
Maximum effective input current I
Material thickness
Dimensions L x W x H
Net/gross weight
This device consists of the following recyclable materials:
Sheet steel, Ccopper, Aluminum, ABS, PE
* The ratio of given duration time/the full-cycle time.
Note 1: This ratio shall be within 0~1, and can be indicated by percentage.
Switch-on time determined at 40°C using simulation
You can find all the technical documents required in the Ecodesign
Regulation 2019/1784 at:
https://www.guede.com/cgi-bin/twinklecom.cgi?param=PAGE&tid=12091&useskscoo
kie=ShopLP&&uniqueid=1616573169181&requestinfo=riMTID%5B%40%40%5D65710
6%3BriSOPT%5B%40%40%5D8&#
the safety measures stated in the service manual. Act
responsibly toward third parties. In case of any doubts
about connection and operation refer please to our
customer center
Specified Conditions Of Use
Welder in protective atmosphere for thermal connec-
tion of ferrous metals by melting edges and including
mixture Do not use this product in any other way as
stated for normal use. Not observing general regula-
tions in force and instructions from this manual does
not make the manufacturer liable for damages.
Ambient temperature -10 °C - +40 °C
1
0
22.9 V
72 A
2
100 %
1max
1eff
Read and understand the
operating instructions before
using the appliance. Abide by all
23.7 V
93 A
60 %
Relative air humidity max. 50 % (40 °C), 90% (20 °C)
Altitude above sea level max. 1000 m
The ambient environment must be free from
abnormal amounts of dust, acids, corrosive gases or
substances.
Please note that our equipment has not been
designed for commercial, craft or industrial use. If the
equipment is used in commercial, craft or industrial
operation or for similar activities, we cannot assume
any liability.
Safety instructions
WARNING! Electric shock! There is a risk of
an injury caused by electric shock!
GIS 161
20029
IP 21S
F
230 V
50/ 60 Hz
16 A
85 V
-
82.1%
26.4 V
160 A
20 %
10 - 160 A
32 A
14.3 A
1 - 9 mm
280 x 130 x 200
mm
4,1 kg / 4,6 kg