Herunterladen Inhalt Inhalt Diese Seite drucken

Appliance-Specific Information; Smoke Control Area United Kingdom; Air Slide Valve And Flue Gas Exhaust; Air Slide Valve - Dik Geurts Ivar 5-01, Low Installationsvorschrift

Vorschau ausblenden Andere Handbücher für Ivar 5-01, Low:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

IN S TA LLA TION M A N U A L

9. Appliance-specific information

The appliance-specific instructions as described in this section prevail over the instructions in the other
!CAUTION
sections! If in doubt follow the instructions in section 9 or contact your supplier.
The appliance-specific information as described in paragraphs 9.1 to 9.4 applies to all models described in
this manual. Supplementary installation instructions (per appliance) are described in paragraph 9.5.

9.1 Smoke control area United Kingdom

The DG Fires Ivar 5-01, Low / Ivar 5, High / Ivar 5, Store, Aste 5 and Soren 5 have been recommended as suitable for
use in smoke control areas when burning wood. In smoke control areas in the United Kingdom the air slide valve
may not be closed too far because of emission laws. A limiting screw is accordingly supplied with all appliances.
This is supplied as a kit in the combustion chamber. This screw is therefore only used in the smoke control areas in
the United Kingdom. In other countries this screw can be disposed of in the appropriate way.
With the installation of an appliance in the United Kingdom:
Ø
Install the screw as shown in Appendix 2, fig. 3. After fitting, the air slide valve cannot be slid further shut
than legally allowed.

9.2 Air slide valve and flue gas exhaust

9.2.1 Air slide valve

When installing and maintaining the appliance, please check the operation of the air slide valve (see Appendix 2,
fig. 4). It is possible that steel grit entered the air slide valve during transport. If the air slide valve does not move
smoothly it must be cleaned. For this purpose, the air slide valve must be disassembled. The suspended air slide
valve is spring-mounted using a bolt and a spring, which are located below the cover plate.
When mounting the air slide valve, please proceed as follows (see Appendix 2, fig. 4):
If an outside air connection has been mounted, it must first be removed, before the air slide valve can be mounted
Caution!
(for removing the outside air connection: see section 9.5).
Ø
Remove the vermiculite plates from the bottom (see section 9.3.1).
Ø
Then remove the little square plate located in a recess below the vermiculite bottom plates.
Ø
Loosen the allen screw using the socket head wrench.
As soon as the bolt has been loosened, the air slide valve will fall down. Make sure you catch the air slide valve!
Caution!
Ø
Check the air slide valve and clean it if necessary.
In order to replace the air slide valve, proceed as described for removal, only in reverse order.

9.2.2 Flue gas exhaust

The flue gas exhaust has a 125 mm (5") diameter connection. The connection can be achieved by means of a fixed
pipe of 125 mm (5") or 130 mm. When using a fixed pipe with a diameter of 130 mm, you should use a special
adapter. This adapter will be available at your supplier. The flue gas exhaust can be connected at the top or rear of
the appliance (see Appendix 2, fig. 2).
In case of a connection at the rear, please proceed as follows:
Ø
Remove the 2 bolts from the exhaust ring mounted at the top of the appliance.
Ø
Remove the bolts from the plate at the rear of the appliance.
Ø
Mount this plate on the top of the appliance, on the location where the exhaust ring used to be.
In case of the Jannik Medium, Low/High, a round plate has to be hammered out of the rear of the appliance, after
!Caution
this plate has been removed (see Appendix 2, fig. 2).
Ø
Mount the exhaust ring at the rear of the appliance by tightening the 2 bolts.

9.3 Interior lining

9.3.1 Vermiculite

The fire's vermiculite plates are located on the bottom and against the rear and side walls of the appliance (see
Appendix 2, fig. 5).
In the following situations the vermiculite plates must be taken out:
When disassembling the air slide valve (see section 9.2.1).
When replacing the vermiculite plates.
The bottom plates are removed first and the rear plates are removed last.
The insertion of the vermiculite plates takes place in reverse order.
Make sure that the vermiculite plates are placed back in their original position! The back plate, for instance, must
!Caution
be placed with the small, not countersunk, holes towards the front.
39

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ivar 5, highIvar 5, storeAste 5Soren 5

Inhaltsverzeichnis