10 Mounting of soffit elements PP 45 LE, PP 45 LEV and PP 45 LEW90 | UK
10 Mounting of soffit elements
PP 45 LE, PP 45 LEV and
PP 45 LEW90
PP 45 LE/LEV/LEW90 not suited for
i
PPB 30 units – use PP 45 LE/LEV/
LEW90 only in combination with
PP 45 units.
Incline of at least 1...2%
L
Window soffit
P Plaster edge max. 7 mm
NOTICE
Installation position, internal wall: Once
the plaster has been applied or wallpaper put
up etc., the wall sleeve must end flush with
the internal wall.
Installation position of window soffit:
The condensate drip edge must protrude
20 to 25 mm beyond the external plastering
once this plastering is applied.
1
Wall sleeve Ø 160, not in scope of supply
2
Rubber seal wall sleeve
3
Soffit element PP 45 LE
4
Stainless steel holder for drip edge and
integrated wall seal [4.1]
4.2 Screws (4 pieces)
5
Soffit external grille
5.1 Screws (2 pieces)
Mounting preparations PP 45 LE
● Determine installation position. Ensure
mounting is on a level wall surface. Note
dimensions. Take account of a 7 mm plaster
edge [P] all the way round.
● Adjust external wall façade insulation to the
soffit element.
! WARNING
Risk of injury if the soffit element or wall
sleeve comes loose. Only mount on walls
with sufficient load-bearing capacity. Firmly
plaster in soffit element and wall sleeve.
33