Fault
The device does not dis-
pense enough water.
The device does not re-
lease any water.
The water quality is im-
paired (contamination,
bad smell / taste).

Warranty

The warranty conditions issued by our relevant sales
company apply in all countries. We shall remedy possi-
ble malfunctions on your appliance within the warranty
period free of cost, provided that a material or manufac-
turing defect is the cause. In a warranty case, please
contact your dealer (with the purchase receipt) or the
next authorised customer service site.
(See overleaf for the address)
Cause
The filter cartridges are clogged.
The water supply is reduced.
The water inlet pressure is too low.
The water supply is interrupted.
The filter capacity of a filter cartridge is
exhausted or the change interval has
been exceeded.
Rectification
 Check compliance with the change inter-
vals of the filter cartridges, replace the cor-
responding filter cartridges if necessary.
If the change interval has not yet been
reached, first replace the left filter cartridge
and vent the device, see Chapter Initial
startup.
If the device continues to dispense too little
water, replace the middle filter cartridge in
the same way.
If the device continues to dispense too little
water, replace the right filter cartridge in the
same way.
 Check the position of the cold water inlet
angle valve and the stop valve, open fully if
necessary.
 Check the condition of the lines, repair
kinks and damage if necessary.
 If the malfunction persists, contact the ser-
vice department.
 Adjust the water inlet pressure to 4 bar on
the pressure reducer of the building's
drinking water installation or on the sepa-
rate pressure reducer.
 If the malfunction persists, contact the ser-
vice department.
 Check the position of the cold water inlet
angle valve and the stop valve, open fully if
necessary.
 Check the condition of the lines, repair
kinks and damage if necessary.
 If the malfunction persists, contact the ser-
vice department.
 Replace the corresponding filter cartridge.
If the change interval has not yet been
reached, first replace the left filter cartridge
and vent the device, see Chapter Initial
startup.
If the water quality is still affected, replace
the middle filter cartridge in the same way.
If the water quality is still affected, replace
the right filter cartridge in the same way.

Technical data

Device performance data
Water supply pressure
Water supply temperature
Ambient temperature
Water dispenser (depending on supply pressure
and filter status)
Filtered water
Dimensions and weights
Width
Depth
Height
Weight
Subject to technical modifications.
English
MPa
0,1-0,4
(bar)
(1-4)
°C
5-38
°C
4-40
l/min
2
mm
377
mm
168
mm
421
kg
5,66
15