Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance And Service; After-Sales Service And Application Service - Bosch GlassVAC Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für GlassVAC:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
10 | English
When the battery charge is low, the charger level indicator
(4) flashes green.
When the charger level indicator (4) flashes red, the battery
must be charged. Switch the machine off and charge the bat-
tery.
Connect the machine to the charger (17) using the micro-
USB cable (16). Plug the charger (17) into the socket. The
charging process begins.
Troubleshooting
Problem
Possible Cause
Machine will not switch
Battery discharged
on
Battery too hot/cold
Restricted or no va-
Suction head blocked
cuum
Drain plug removed
Machine turns itself off Battery too hot/cold
Suction head blocked
Water leaks from ma-
Spray applicator not mounted correctly
chine
Battery will not charge Battery charger not connected correctly
Battery too hot/cold
Streaking on windows Wiper blade damaged
Too much force applied
Too little force applied

Maintenance and Service

Maintenance and Cleaning (see figures J–K)
Always clean the product thoroughly after use.
Remove the suction head from the main body and rinse.
Whilst suction head (2) is removed from the machine, fill the
dirty water tank (7) via the suction head aperture to the max
line with clean, warm water. DO NOT fill the dirty water tank
(7) via the drain hole. Shake the machine and pour the water
out via the drain plug(8).
Maintenance of the suction head
Protect the suction head against damage during storage.
Prevent the wiper blade from touching paper or cardboard,
as this could damage the wiper blades polymer coating.
Spots or lines may be visible on the polymer coating. This is
normal and does not affect the cleaning performance.
Textiles
Microfiber cloths: 67% polyester, 14% polyamide, 19%
polypropylene

After-Sales Service and Application Service

Our after-sales service responds to your questions concern-
ing maintenance and repair of your product as well as spare
parts. You can find explosion drawings and information on
F 016 L81 778 | (16.08.2022)
During the charging procedure, the handle of the machine
warms up. This is normal.
The charger level indicator (4) continuously lights up red
during the charging procedure. When the battery is fully
charged, the charger level indicator (4) continuously lights
up green.
Disconnect the battery charger from the mains supply when
charging process ends.
Observe the notes for disposal.
Corrective Action
Recharge battery
Allow to cool/warm
Unblock suction head
Replace drain plug
Allow to cool/warm
Unblock suction head
Mount the spray applicator correctly
Check battery charger and USB cable connec-
tions
Allow to cool/warm
Replace wiper blade (accessory)
Apply reduced force
Apply more force
spare parts at: www.bosch-pt.com
The Bosch product use advice team will be happy to help you
with any questions about our products and their accessor-
ies.
In all correspondence and spare parts orders, please always
include the 10‑digit article number given on the nameplate
of the product.
Great Britain
Robert Bosch Ltd. (B.S.C.)
P.O. Box 98
Broadwater Park
North Orbital Road
Denham Uxbridge
UB 9 5HJ
At www.bosch-pt.co.uk you can order spare parts or arrange
the collection of a product in need of servicing or repair.
Tel. Service: (0344) 7360109
E-Mail: boschservicecentre@bosch.com
You can find further service addresses at:
www.bosch-pt.com/serviceaddresses
Transport
The contained lithium-ion batteries are subject to the Dan-
gerous Goods Legislation requirements. The user can trans-
port the batteries by road without further requirements.
Bosch Power Tools