Bottom view

1 DC IN connector
The AC adapter cable is connected here.
2 DIP switches
This bank of three switches sets the operation mode of the unit. The switch functions
are as follows.
1
2 3
Factory default settings
Switch 1: OFF
For details on DIP switch settings, refer to the section "DIP Switch Settings" on page
17.
3 Reset switch
By pressing this switch with a paper clip or other pointed object, you can reset stored
settings (information about bonded notebooks, Passkey string) to the factory defaults.
The device name will not be changed by a reset.
Notes
• To prevent the possibility of unit damage, do not push the reset switch with the tip of a
pencil or other object that may break.
• If the device name of the unit has been changed, the name will not revert to the initial
setting even when the reset switch is pressed.
4 LINE connector
To connect the unit to the telephone line, plug the supplied telephone cable into this
jack.
5 Serial number label
The serial number of the unit is shown here.
1 3
Switch 1 (Setup/normal operation mode selector)
Switch 2 (Always set to OFF in Europe)
Switch 3 (Private ON/OFF selector)
ON
r
Switch 2: OFF
2
4
5
Switch 3: ON