Lubrication

Pneumatic tools have to be lubricated always sufficiently. This is done
continuously and safest by using an oil-fog lubricator. If the oiler is mounted
centrally at the compressor or mounted firmly at the end of the compressed-air
pipe installation, use only a hose with a length of max. 10 m. If the hose is longer,
the nebulisation disappears in the air. The oil floats inside the hose and does not
arrive at the air tool.

Oiler Setting

Hose up to 5 m
Hose up to 10 m
If you do not have an oiler at yours disposal, please put a few drops of oil into the
compressed-air connection before every machine usage. Lubricate the air
engraving pen once more after use, especially if you do not operate the unit for a
long time. Further maintenance work is not necessary.

Suggested Components for safe Operation

1.
1. Air Engraving Pen
3. Pneumatic Pipe with Quick Couplers 4. Quick Coupling Adaptor
5. Quick Coupling
7. Oil-fog Lubricator
9. Filter Unit

Storing

Store the unit in a dry, dust and dirt-free location, between 10°C and 30°C and
keep the unit out of reach of children and persons in need of supervision.
Operation
every 2 min.
always per min.
2.
3.
1 drop
1 drop
5.
4.
6.
2. Quick Coupling Adaptor
6. Valve
8. Pressure Regulator
10. Air Source/Compressor