Herunterladen Inhalt Inhalt Diese Seite drucken

Circuit Diagram - LG AQLA Einbauanleitung

Temperaturgesteuerte verflüssigungsdruckregelung (single wandgeräte)
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 9
1. Check SW01F. If it doesn't indicate to PIPE , Switch it to PIPE .
2. With the unit running in cooling mode, allow the system to settle. Observe surface temperature of suction pipe.
3. Should setting be necessary, switch off electrical supply, adjust the set point P1(Refer to Fig. 1, Table).
Switch on the electrical supply. Repeat this procedure until the suction temperature is between 0°C and +5°C.
4. Keep the unit operating on cooling mode at least 30 minutes.
If cycle isn't stable, switch off electrical supply, adjust switch P2 (Refer to fig. 2, graph).
Repeat this procedure unitl system is stable.
* Caution: SW01F should indicate PIPE to work properly. Ensure SW01F indicate PIPE .
FIGURES OF OPTION SWITCHES
Rotating part (use a proper tool to rotate)
F 0
1
E
2
D
3
C
4
B
5
A
6
9
7
8
Fig. 1: Rotary S/W P1
Fig. 2: Rotary S/W P2
(default:4)
TABLE
Opt 0
Opt 1
Opt 2
Opt 3
Opt 4
Opt 5
PRESET TEMP
19°C
20.5°C
22°C
23.5°C
25°C
26.5°C
FAN OFF TEMP
2°C
3.5°C
5°C
6.5°C
8°C
9.5°C
FAN ON TEMP
4°C
5.5°C
7°C
8.5°C
10°C
11.5°C
Table : Setting Temperatures ; Controlled by rotating P1
GRAPH
100
90
80
70
60
50
40
30
20
10
0
Preset temperature (°C)
Graph : Speed ratio(%) ; Controlled by rotating P2
ROOM
F 0
1
E
2
D
3
C
4
B
5
A
6
9
7
8
PIPE
Fig. 3: S/W SW01F
(default:8)
(default: PIPE )
Opt 6
Opt 7
Opt 8
Opt 9
Opt 10
Opt 11
Opt 12
Opt 13
28°C
29.5°C
31°C
32.5°C
34°C
35.5°C
37°C
38.5°C
11°C
12.5°C
14°C
15.5°C
17°C
18.5°C
20°C
21.5°C
13°C
14.5°C
16°C
17.5°C
19°C
20.5°C
22°C
23.5°C
Opt F
Opt E
Opt D
Opt F
Opt C
Opt B
Opt A
Opt 9
Opt 8
Opt 7
Opt 0
Opt 6
Opt 5
Opt 4
Opt 3
Opt 2
Opt 1
Opt 0
(MOTOR)
L
MAIN
INPUT
N
N
SUPPLY
TO FAN(S)
L
FROM 4 WAY VALVE

CIRCUIT DIAGRAM

(COOLING Only Type)
[EX 1]
Opt 14
Opt 15
40°C
41.5°C
23°C
24.5°C
25°C
26.5°C
(HEAT-PUMP Type)
[EX 2]
1
P.C.B.
2
ROOM
3
4
SW01F
5
PIPE
6
7
8
9
P1
1 = Live input
2 = Neutral input
Sensor
3 = Neutral output (to motor)
4 = Live output (to motor)
5 = Do not use
6 = Live from 4 way valve
7 = Neutral from 4 way valve
8 = sensor
9 = sensor
Low Ambient Controller
Low Ambient Controller
P2

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis