Changing the mobile services pro-
vider
Note
Before changing, check whether the de-
sired mobile network is available where the
plant/system is installed.
Keep the SIM card and the corresponding
PIN number ready.
Only SIM cards with 3V power supply may
be used. The voltage details are printed on
the SIM card.
For prepaid cards, ensure that you have
enough balance on the card.
Turn the RDS1 switch to "0".
Press release button of the SIM card
holder.
Take out the SIM card holder.
Remove the SIM card from the card
holder.
Re-insert the SIM card holder.
Switch on the main switch of the wash-
ing unit.
Unlock all emergency-stop buttons of
the washing unit.
Press control supply voltage/normal po-
sition button on the operating point of
the washing unit.
Pull out the plug (for controlling the
washing unit) from the interface of the
GSM modem.
Connect the interface of the GSM mo-
dem with the serial port of the PC.
Turn the RDS1 switch to "1" - the GSM
modem is being initialized:
The "Connect" LED glows for approx. 4
seconds.
- after another 8 seconds the LED sta-
tus starts to blink for approx. 20 sec-
onds
The "Signal" LED displays the strength
of the reception signal. Faster the LED
blinks, so much better is the reception.
Start the configuration software "HS-
Com" on the PC.
The programme automatially establish-
es the link to the GSM modem.
1 "New PIN" checkbox
2 "Basic Settings" tab
3 PIN input field
4 Input field: Service Centre Number
5 "Synchronise RS232" button
6 "Send values" button
7 "Read settings" button
Note
If the message "Monitoring time expired" is
displayed, it means the connection cannot
be established automatically. In such a
case, click the "Synchronise RS232" button
followed by the "Read settings" button in
the screen. This process can take approxi-
mately 1 minute. Repeat the process if error
messages are displayed.
Activate the Basic Settings tab.
Activate the "New PIN" checkbox.
Enter the new PIN for the SIM Card in
the PIN input field.
Enter the Service Centre Number of the
mobile operator in the Service Center
Number field.
Note
The Service Centre Number is needed for
sending SMS and can be found in the doc-
uments of the mobile phone operator.
Some Service Centre numbers are given in
the appendix to the manual of the GSM mo-
dem.
Click "Send values" button
Note
The new PIN is stored in the GSM modem
and is used for logging on to the GSM net-
work during every fresh start.
Exit the configuration program on the
PC.
Turn the RDS1 switch to "0".
Press release button of the SIM card
holder.
Take out the SIM card holder.
Place the new SIM card in the card hold-
er.
Re-insert the card holder with SIM card
- the contacts of the SIM card must point
towards the left.
Disconnect the connection cable to the
PC at the GSM modem interface.
Insert the plug for controlling the wash-
ing unit into the interface of the GSM
modem.
Turn RDS1 switch to "1" - the initializa-
tion process starts.
The initialization process is completed
after approx. 90 seconds.
The "Power" and "Status" LEDs start to
glow.
The "Signal" LED displays the strength
of the reception signal. Faster the LED
blinks, so much better is the reception.
Change the receiver of messages
Turn the RDS1 switch to "0".
Pull out the plug (for controlling the
washing unit) from the interface of the
GSM modem.
Connect the interface of the GSM mo-
dem with the serial port of the PC.
Turn the RDS1 switch to "1" - the GSM
modem is being initialized:
The "Connect" LED glows for approx. 4
seconds.
- after another 8 seconds the LED sta-
tus starts to blink for approx. 20 sec-
onds
The "Signal" LED displays the strength
of the reception signal. Faster the LED
blinks, so much better is the reception.
Start the configuration software "HS-
Com" on the PC.
The programme automatially establish-
es the link to the GSM modem.
Note
If the message "Monitoring time expired" is
displayed, it means the connection cannot
be established automatically. In such a
case, click the "Synchronise RS232" button
followed by the "Read settings" button in
the screen. This process can take approxi-
mately 1 minute. Repeat the process if error
messages are displayed.
Click "Alarm/Switch1" tab; you can now
modify the settings given below it.
1 Starting text of the message, for e.g. lo-
cation or description of the plant, maxi-
mum length 90 characters
2 "Alarm/Switch1" tab
3 Telephone number to which the inter-
ruption messages are sent
4 Telephone number to which the counter
statuses are sent
Note
The counter statuses can only be sent to
the receivers entered in this screen.
Click "Alarm/Switch2" tab; you can now
modify the settings given below it.
1 Message text when control voltage is
switched off by pressing the Emergency
Stop button or released engine protec-
tion switch
2 "Alarm/Switch2" tab
3 Telephone number to which this inter-
ruption (message) is sent
English
7