Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications; Warning Device Lal-Srw3 - Pepperl+Fuchs LAL-SRW3 Handbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

WARNING DEVICE LAL-SRW3

Technical specifications

7
Technical specifications
7.1
Warning Device LAL-SRW3
Power supply
Rated voltage
Power consumption
Max. fusing
Overvoltage category
Connection
Maximum voltage U
Input
Overflow sensor NVF-104/34-PF
connection
U
o
I
o
P
o
R
o
C
o
L
o
Oil level sensor KVF-104-PF
connection
U
o
I
o
P
o
R
o
C
o
L
o
Sludge level sensor SLU-103-**
connection
U
o
I
o
P
o
R
o
C
o
L
o
Oil level sensor KVF-104-PF
connection
U
o
I
o
P
o
R
o
C
o
L
o
230 V AC ± 10%, 50 Hz ... 60 Hz
6 VA
10 A
III
terminals 5, 6, 7
253 V
m
terminals 13, 15
21.0 V
256 mA
1.16 W (trapezoid characteristic)
165.7 Ω
0.5 µF
0.5 mH
terminals 18, 20
10.5 V
92.2 mA
0.25 W (linear characteristic)
114.0 Ω
3.1 µF
5 mH
terminals 18, 20
10.5 V
92.2 mA
0.25 W (linear characteristic)
114.0 Ω
5 µF
1 mH
terminals 22, 24
10.5 V
92.2 mA
0.25 W (linear characteristic)
114.0 Ω
3.1 µF
5 mH
EN
EN - 31

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis