B. LED Indicator
1. Red LED OFF = system is OFF
2. Red LED flashes fast = system is ON
3. Red LED flashes once + pause = Indicates attempted intrusion detected via the current sensor
4. Red LED flashes twice + pause = Indicates attempted intrusion detected via the pin switch or additional sensors
that have been installed
5. Red LED flashes three times = Indicates attempted intrusion detected via the shock sensor.
6. Red LED flashes = automatic activation of alarm after 30 seconds.
C. Audible and Visible Alarm Indication
1 beep + parking light = alarm is activated
2 beeps + parking light = alarm is deactivated
4 beeps and parking light = alarm is deactivated and activated again
D. Alarm System
1
siren
2
status engine
3
orange wire
4
door lock interface
5
red LED
6
parking light
E. Manual Activation
1. Press button I on the sender.
2. The siren will emit 1 beep and the system will be fully armed 5 seconds later.
REMARK
: ACTIVATE THE SHOCK SENSOR WITH THE REMOTE TRANSMITTER
In parking garages with several floors vibrations can occur frequently. Sometimes the system can
react to these vibrations. Use the remote control to program the shock sensor.
"ANTI-TAMPER MODE"
When the shock sensor is activated, the intruder will hear a warning tone that tells him to turn back. If
he doesn't listen and the shock sensor picks up more than 3 shocks in 20 seconds, then the anti-theft
alarm will activate the siren. Press transmitter button I to activate this system.
3. DEACTIVATE the shock sensor
The shock sensor can be deactivated at any given time. Activate the alarm then press button II within 5 seconds. The
alarm system deactivates the shock sensor automatically.
F. Manual Deactivation
1. Press transmitter button I.
2. The siren will emit two beeps to indicate that the alarm has been deactivated.
REMARK
: 1. DEACTIVATING THE ALARM WHEN IT'S BEEN TAMPERED WITH: If the alarm has been
triggered, then the siren will produce 4 beeps and the parking lights will flash three times when you
want to deactivate the alarm. The red LED will indicate which zone has activated the alarm.
2. AUTOMATIC REACTIVATION: This alarm system is equipped with an automatic, passive rearming
circuit that will fully reactivate the system if none of the doors (the dome light should be on and
SP500B
Activate
Deactivate
1 tone
2 or 4 beeps
engine OFF
ground
close
open
flash
OFF
1 flash
2 or 4 flashes
Alarm Triggered
wails
engine OFF
ground
flash
flash
6
Panic Function
wails
engine OFF
ground
close
flash
flash
VELLEMAN

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis