Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Control
Manual control
• Plug the mains cable into a mains socket
• Open the shutter (6) in front of the laser outlet (5) (exists only in laser module 10
mW)
by turning the cover plate away from the laser outlet (5).
• Switch on the mains adapter with the key switch (2).
• Push the on/off switch (4), the laser beam is activated. Push it again, and the laser
beam is deactivated.
• Close the shutter (6) after operation.
External modulation of the laser beam
• Connect a control signal (TTL-level, 10 kHz max.) to the control socket (1).
Use the enclosed plug adapter.
Connecting possibilities:
red cable
black cable
modulation signal
0V (earth)
+5V
modulation signal
• Plug the device into the mains socket
• Open the shutter (6) in front of the laser outlet (5) (exists only in laser module 10
mW), by turning the cover plate away from the laser outlet (5).
• Switch on the mains adapter with the key switch (2).
• As soon as the modulation signal appears, the laser beam will be switched on and
off (modulated) in the rhythm of the signal.
• The on/off-switch (4) must remain turned off for this operation mode, otherwise the
manual control (see above) will be activated.
• Close the shutter (6) after operation. (Exists only in laser module 10 mW).
Disposal
Please dispose of the used product according to the legal regulations.
16
output
signal high > laser on
signal low > Laser off
signal high > laser off
signal low > laser on

Technical data:

Laser module 10 mW
Operational voltage
Power consumption
1.5 / 6.5 W (standby /
(Adapter)
operation)
Laser wave length
Laser wave length
10 mW
Laser class
3B
Modulation input
Diameter of the beam
< 2mm in 1m distance
Beam divergence
Warming up
Polarisation
Lifetime (with 8h
Operation time / day
Current consumption
< 1.2 A
Optimal
ambient temperature
Annex
Adresses, where you can ask for information on safe operation and for the respective
legal regulations:
• Safety regulations - Unfallverhuetungsvorschriften
Gesetzliche Unfallversicherung
Berufsgenossenschaft der Feinmechanik und Elektrotechnik
Unfallverhuetungsdienst
Gustav-Heinemann-Ufer 130
D-50968 Koeln
• DIN standards
Beuth Verlag GmbH
Burggrafenstr. 6
D-10787 Berlin
Laser module 3 mW
90 to 240 VAC / 50 to 60 Hz
1.5 / 4 W (standby /
operation)
532 nm
3 mW
3A
TTL-level, 10 kHz max.
< 2mm
< 1mrad
approx. 15 min
linear
> 5000 h
< 0.7 A
20 to 30 °C (operation)
0 to 50 °C (storage)
17

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

18 76 46