2.7

Charging station

1
2
3
8
5
7
6
No.
Component
1
Base plate
2
LEDs for status display
3
Charging contact
4
Charging station
5
Cable shaft
6
Wheel recess
7
Hole for grass screws (8)
8
Grass screws
2.8

Integrated battery

The battery is installed permanently in the appli-
ance and may not be changed by the user.
NOTE
Fully charge the rechargeable battery
before using it for the first time. The re-
chargeable battery can be charged in
any charge status. Interrupting charging
does not damage the rechargeable bat-
tery.
The rechargeable battery can only be
charged after the appliance has been
switched on.
The integrated battery is partially charged on
delivery. The battery is regularly recharged
during normal operation. The appliance re-
turns to the charging station for this.
The integrated electronic control unit with a
monitoring function terminates the charging
procedure when a 100% charge status is
reached.
42
The charging process only functions with per-
fect contact of the charging contacts on the
3
4
charging station with the contact surfaces of
the appliance.
The built-in protection circuit prevents the
battery from being charged at temperatures
above 45 °C. This prevents irreparable dam-
age to the battery.
If the operating time of the battery is reduced
in spite of it being fully charged, have the bat-
tery replaced by a new genuine battery. This
task should be carried out by a Kärcher deal-
er, technician or service partner.
If the battery charge level has dropped below
the threshold set by the manufacturer as a
result of ageing or excessively long storage,
this means it can no longer be recharged.
5
Have the battery and the monitoring electron-
ic control unit checked by a Kärcher dealer,
technician or service partner, and replace
them if necessary.
The battery status is shown on the display.
Check the battery status after about 3
months in storage. To do so, switch on the
appliance and read off the battery status. If
the rechargeable battery is now only charged
to approx. 30 % or less, place the appliance
in the charging station and switch it on so the
rechargeable battery is charged. If the
charging pole was removed to store the
charging station (see chapter 11.2 "Storing
the charging station", page 57), first install it
again in reverse order and connect the
charging station to the mains supply again.
If electrolyte has escaped into the appliance:
Have the appliance repaired by a Kärcher
service centre.
If the rechargeable battery has been re-
moved from the appliance: If the eyes or
hands have come into contact with escaped
electrolyte, flush them immediately with wa-
ter. Immediately consult a doctor.
2.9

Functional description

Moving on the grass surface
The appliance moves freely in a mowing area de-
limited by a boundary cable. The appliance is ori-
ented by sensors that detect the magnetic field of
the boundary cable.
If the appliance encounters an obstacle, it stops
and then continues in another direction. If the ap-
pliance detects moisture, it automatically returns
to the charging station. If the appliance gets into
a situation where it cannot operate, this is indicat-
ed by a message on the display.