  • DEUTSCH, seite 1
Engine protection switch
– The engine protection switch interrupts
the electric circuit if the engine is over-
loaded.
Temperature stop for exhaust gases
– The temperature stop switches off the
machine when the waste gases have
reached very high temperatures.

Start up

Danger
Risk of injury! Device, tubes, high pressure
hose and connections must be in faultless
condition
Lock parking brake.
Check oil level
Figure 1 - Pos. 15
Warning
In case of lacteous oil inform Kärcher cus-
tomer service immediately
If oil level approaches the MIN marking,
fill oil until MAX marking
Close oil refill nozzle
For oil type refer to technical specifica-
tions.
Refill liquid softener
Only HDS 558.../601.../698.../798...
Note
A sample bundle of liquid softener is includ-
ed
Figure 1 - Pos. 14
The liquid softener prevents the calcification
of the heating spiral while operating with cal-
ciferous tap water It is dosed into the supply
drop by drop
The metering is set to medium water rigidity
by the manufacturer
For other water rigidity call for Kärcher
customer service and have it adapted to
local facts

Refill fuel

Figure 1 - Pos. 3
Warning
Never operate device with empty fuel tank
The fuel pump will otherwise be destroyed.
Danger
Risk of explosion! Only refill diesel oil or light
fuel oil. Unsuitable fuels, e.g. petrol, are not
to be used.
Close tank lock.
Wipe off spilled fuel.
Refill detergent
Danger
Risk of injury!
– Use Kärcher products only.
– Under no circumstances fill solvents
(petrol, aceton, diluting agent etc.)
– Avoid eye and skin contact.
– Observe safety and handling instructions
by the detergent manufacturer.
Kärcher offers an individual cleaning and
care appliances program.
Your dealer will consult you gladly.
Figure 1 - Pos. 8
Refill detergent.
Install hand spray gun
Connect ray tube with hand spray gun
Insert high pressure nozzle into covering
nut
Install covering nut and tighten firmly
Figure 1 - Pos. 10
Connect the high pressure host to the
high pressure connection point of the
machine.
27