Fault
The appliance turns on,
but the temperature is
too high/low
The appliance is
leaking water
The appliance is
unusually loud
Technical Specifications
Note: Due to our continuing program of research and development, the specifications herein may be
subject to change without notice.
Model
Voltage
Power Current
GL180
220-240V~
330W
50Hz
GL181
700W
Note: For optimal product performance and efficiency, please ensure to mind the net usable capacity (load
limit) when filling.
GL180-GL181_ML_A5_v7_20230427.indb 7
GL180-GL181_ML_A5_v7_20230427.indb 7
Probable Cause
Too much ice on the evaporator
Condenser blocked with dust
Doors are not shut properly
Appliance is located near a
heat source or air flow to the
condenser is being interrupted
Ambient temperature is too high
Unsuitable foodstuffs are being
stored in the appliance
Appliance is overloaded
The appliance is not properly
levelled
The discharge outlet is blocked
Movement of water to the drain is
obstructed
The water container is damaged
The drip tray is overflowing
The safety band has not been
removed
Loose nut/screw
The appliance has not been
installed in a level or stable
position
Temperature
Range
2.0A
2°C ~ 8°C
4.9A
-22°C ~ -18°C
Solution
Defrost the appliance
Clean the Condenser
Check doors are shut and seals are not
damaged
Move the refrigerator to a more suitable
location
Increase ventilation or move appliance to a
cooler position
Remove any excessive hot foodstuffs or
blockages to the fan
Reduce the amount of food stored in the
appliance
Adjust the screw feet to level the appliance
(if applicable)
Clear the discharge outlet
Clear the floor of the appliance (if
applicable)
Consult a qualified Technician
Empty the drip tray (if applicable)
Remove the safety band
Check and tighten all nuts and screws
Check installation position and change if
necessary
Net
usable
Dimensions
Refrigerant
Capacity
H x W x D mm
(Ltr)
534
R290
2010 x 740 x 990
534
R290
2010 x 740 x 990
EN
Weight
(kg)
161
170
7