Operating the appliance

These instructions apply to several appliance variants. It is
possible that individual features are described which do not
apply to your appliance.
Note: Switch on the extractor hood when you start cooking and
switch it off again several minutes after you have finished
cooking. This is the most effective way of removing the kitchen
fumes.
Control panel model 1 and 2
Explanation
0, A
Light on/off
1
Fan speed 1
2
Fan speed 2
3
Fan speed 3
Setting the fan
Switching on
Pull out the filter pull-out. The fan starts at the selected level.
Press buttons 1, 2 or 3 in order to change the fan strength.
Switching off
Slide the filter pull-out in as far as the limit stop.
Note: When you pull out the filter pull-out again, the fan starts
up at the fan speed that was last selected.
18
All manuals and user guides at all-guides.com
Control panel model 3
Explanation
Light on/off
<
Fan on/off
#
-
Reduces the fan speed
+
Increases the fan speeds/intensive setting
Setting the fan
Switching on
Pull out the filter pull-out and press the # button. The fan starts
at setting 2.
Press the + or - button to change the fan strength.
Switching off
Press the # button. Slide the filter pull-out in.

Intensive setting

You can use the intensive setting if there is a large build-up of
odours and fumes/vapours.
Press the + button until all of the LEDs in the display light up.
The intensive setting is activated.
After approx. six minutes, the electronics automatically reduce
the fan to a lower setting . If you want to end the intensive
setting before the preset time expires, press the - button until
the required fan setting is reached.
The run time is limited. The fan is then automatically reduced to
a lower fan setting. You can switch back manually at any time.
Fan run-on time
If you slide in the filter pull-out, the run-on time will be activated
for as long as the extractor hood is operating.
After approx. 10 minutes, the fan switches off automatically.
Lighting
The lighting can be switched on and off independently of the
ventilation.
Press the A button.