8.7.
Saving to memory and loading
This model of welding machine provides the function of saving and recalling from memory. It has up to 18 memory
locations for welding tasks.
8.8.

Restore factory settings

Just hold down the "Return" button for 5 seconds and the machine system will reset to factory settings.

9. Disposal of the packaging

Please keep all packaging material (cardboard, plastic strips and polystyrene foam) to ensure that the unit is
protected during shipment, should it become necessary to send it to a service center!
10.

Transport and storage

When transporting the unit, protect it from shocks and tipping over, and do not place it "upside down". Store the unit
in a well-ventilated room where dry air is present and corrosive gases are not present.
The value of the current in the "Force current"
function
It stabilizes the arc regardless of fluctuations in its
length and reduces the amount of spatter.
VRD function
Press the button to activate the VRD function. Green
light means VRD is on. Press the button again to
deactivate the function. It is recommended to turn
on the VRD function during MMA welding. VRD - a
voltage reduction system; its task is to turn off the
power supply within a few milliseconds after the end
of welding. This function is also responsible for
reducing the voltage of the coated electrode to a
safe level.